CONNECTIONS
DEFAULT SETTINGS
PASSWORD = Not programmed
Delay On: 0 minutes
Enable (optional): active
Broken Hose (optional): active
Dosing: Pulses
N pulses: 1
mL Dos: 10ml
%Flowrate: 10%
Memory: deactive
DEFAULT SETTINGS RESTORE
3sec
Rev 1.1
A - Power cable, 90-250V-50-60Hz
B - Enable input (dosing consent)
C - Alarm output connector (3 and 4 contacts).
D - Level probe connector (3 and 4 contacts).
E - Connector for pulses input from water meter
F - ON_OFF switch. OPTIONAL
Keep pushing for 3 seconds the ENTER / MENU button to
enter into the programming menu.
Move the cursor > to Utility by pressing ▼. Push ENTER
button to enter the submenu.
Push ▼ button to move the cursor to "Reset".
Push ENTER button to confirm.
By pushing the ▼ button choose "YES" to confirm and push
ENTER button.
Automatically the pump restores the factory settings.
Press the ESC button for 3 seconds to exit programming.
Cod. 00.009.123
(110Vac; 230Vac; upon request 24V).
OPTIONAL
( 5A 250Vca/30Vdc) NORMALLY OPEN.
OPTIONAL.
OPTIONAL.
(contacts 3 and 4).
18