Temperature adjustment buttons
1
Applications
The RLV3100 thermostat can be used to control an electric heating
system such as an electric baseboard heater, a radiant ceiling, a
radiant floor, a convector, etc.
The thermostat cannot be used with the following:
a resistive load under 2 A
a resistive load over 12.5 A
systems driven by a contactor or a relay (inductive load)
fan-forced heating systems
central heating systems
2
Supplied Parts
One (1) thermostat
Two (2) 6-32 mounting screws
Two (2) solderless connectors
3
Installation Procedure
TURN OFF POWER OF THE HEATING SYSTEM AT THE MAIN
POWER PANEL TO AVOID ELECTRIC SHOCK.
Loosen
the
screw
underneath the thermostat
and separate the front plate
from the base plate.
The screw cannot be
completely removed.
Connect the thermostat wires to the power and to the load using
solderless connectors for copper wires. The thermostat wires are not
polarized; meaning either wire can be connected to the load or to the
power supply.
All cables and connections must comply with local electrical
codes. This thermostat has tinned copper wires for line and
load connections. Special CO/ALR solderless connectors must
be used if these wires will be connected to aluminium
conductors.
RLV3100
2-wire Installation
Temperature
display
4-wire Installation
1.
2.
Mount the back plate to the electrical
box using the provided screws. Insert
the screws through the left or right pair
of mounting holes of the back plate.
3.
Set the switch on the back of the
front plate to °C or °F to select
the temperature display format.
Re-install the front plate of
the thermostat on the base
plate and secure it in place
with the screw underneath
the thermostat.
Apply power to the heating system. Verify the installation by checking
that the heater can be turned On and Off by raising and lowering the
setpoint using the
Digital Non-programmable Thermostat
If there is a protective film or sticker on the display, peel it off.
buttons.
RLV3100
Owner's Guide
1/2

Publicidad

loading

Resumen de contenidos para Honeywell RLV3100

  • Página 1 Temperature adjustment buttons 4-wire Installation Applications The RLV3100 thermostat can be used to control an electric heating system such as an electric baseboard heater, a radiant ceiling, a radiant floor, a convector, etc. The thermostat cannot be used with the following: •...
  • Página 2 SOLUTIONS This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or This is normal. Under normal operation, the malfunction was caused by damage which occurred while the Thermostat is hot.
  • Página 3 Botones de ajuste de la temperatura Aplicaciones Instalación a cuatro hilos El termostato RLV3100 puede ser utilizado para controlar un sistema de calefacción eléctrica como calefacción por zócalo, suelo radiante, techo radiante, convectores, etc. El termostato no puede ser utilizado con lo siguiente: •...
  • Página 4 Corte de luz fechada, en el lugar donde lo compró; o (ii) comuníquese con el Centro de atención al cliente de Honeywell al El control de ajuste se almacena en una memoria no volátil y no se 1-800-468-1502. Atención al cliente decidirá si se debe devolver el borra en caso de un corte de electricidad.