Description
This thermostat can be used to control an electric heating system
such as an electric baseboard heater, a radiant ceiling, a radiant
floor, an electric convector, etc.
The thermostat cannot be used with the following:
•
a resistive load under 2 A
•
a resistive load over 14.6 A
•
systems driven by a contactor or relay (inductive load)
•
central heating systems
SUPPLIED PARTS
•
One (1) thermostat
•
Two (2) 6-32 mounting screws
•
Two (2) solderless connectors
Installation
TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN
POWER PANEL TO AVOID ELECTRICAL SHOCK.
All cables and connections must conform to the local electrical
code.
Special CO/ALR solderless connectors must be used when con-
necting with aluminum conductors.
Install the thermostat onto an electrical box.
Install the thermostat about 5 feet high, on an inside wall facing
the heater.
Avoid locations where there are air drafts (such as the top of a
staircase or an air outlet), dead air spots (such as behind a
door), or direct sunlight.
Do not install the thermostat on a wall that conceals chimney or
stove pipes.
The thermostat wires are not polarized; either wire can be con-
nected to the load or to the power supply.
RLV430
Set the time
Program the schedule
End
programming
Indicates that the
thermostat is configured
to conventional control
Heating power
indicator
Period no. in
Automatic mode
Automatic
mode
1) Connect the thermostat
1.
Connect the thermostat wires to the power and to the load using
solderless connectors for copper wires.
2-wire installation
2.
4-wire installation
RLV430