tainer/case only.
Note: During transport On/Off compensator lock (3) must be set to
position "OFF". Disregard may lead to damage of compensator.
Specific reasons for erroneous measuring results
•
Measurements through glass or plastic windows;
•
Dirty laser emitting window;
•
After instrument has been dropped or hit. Please
check the accuracy.
•
Large fluctuation of temperature: if instrument will
beused in cold areas after it has been stored in warm
areas (or the other way round) please wait some
minutes before carrying out measurements.
Electromagnetic acceptability (EMC)
•
It cannot be completely excluded that this instru-
ment will disturb other instruments (e.g. navigation
systems);
•
will be disturbed by other instruments (e.g. intensive
electromagnetic radiation nearby industrial facilities or
radio transmitters).
Laser class 2 warning label on the laser instrument
Laser classification
The instrument is a laser class 2 laser product accortding to
DIN IEC 60825-1:2007 and Class II in accordance with CFR
21 § 1040 (FDA). This tool may be used without need for fur-
ther protective measures.
Safety instructions
Please follow up instructions given in operators' manual. Do
not stare into beam. Laser beam can lead to eye injury (even
from greater distances). Do not aim laser beam at persons
or animals.