To PAT test the Electrolux Range of Food Preparation Equipment,
the PCB board needs to be disconnected before any test is done.
This is due to the fact that the boards are fi tted with a grounding
diode that can give incorrect result during such a test. Also on
a standard appliance a fl ash test of 25 amps and up to 3000v is
used but, as you would expect, to use this on equipment, which
has a printed circuit, board would be quite destructive to that
board. We would recommend the use of a PAT tester approved
for computer systems which use a lower rate of amps.
Use, safety
3.
BUILT-IN SAFETY - GUIDELINES
1
• The safety of the user is guaranteed in accordance with the
UL 763 by:
- The need to press on both the ON pushbuttons items O and
M after a STOP («no volt release system»).
- The need to hold down button rep. M to ensure the motor
works.
- The motor is protected against excess voltages by a thermal
fuse.
- The distance between the tool and handling areas.
- The protection of the mixer tool.
- The following safety guidelines being respected.
• The user of the Mixer - Whisk must respect the following safety
guidelines:
- The machine must always be unplugged before fi tting or
removing the mixer and whisk equipment.
3.
OPERATION
2
a) Starting up:
- Respect the safety instructions in § 3.1.
- Hold the mixer using handles A and B on the motor unit C.
- Press simultaneously on button «I» item M and the green
button «+» item O. The mixer starts to operate at speed 3 for
the 350W and 450W models, and at speed 2 for the 550W
650W and 750W models.
- Release button «+» item O while still holding the green button
item M pressed in.
b) Stopping the machine
- Release the green button item M.
c) Choice of speed
If the appliance has been stopped for more than 30 seconds, it
will always re-start at speed 3 in the case of the 350W and 450W
models, and at speed 2 for the 550W, 650W and 750W models.
If the appliance has been stopped for less than 30 seconds, it will
start again at the speed at which the mixer was operating when
it was stopped, the reason being to avoid having to adjust the
speed after a short stop (of less than 30 seconds), for example
to check the preparation.
d) To increase the speed
Press several times in succession on the green «+» button
item O.
The speed changes by gradual steps with each press on the
green «+» button item O.
B3000 GB 12 2015
1.
1
The appliance is perfectly safe and is CE certifi cated. There are
two ways to get overcome this problem.
· Disconnect the board as instructed and test using test for
PC's,
· Or install the mixer on a fused spur (no plug) as this takes it
away from being a portable appliance and the PAT test is then
not needed.
- Never operate the machine when not in a recipient and
only immerse the tool to 2/3 of its length at most. (see
immersion limit)
- Always use a stable recipient at a suitable height.
- In order to avoid splashing hot liquids, before starting the tool
lower it to the bottom of the container, respecting the immersion
limit, and remove it after it has completely stopped.
- To prevent risks linked to the blade rotation, always start the
mixer in the recipient.
- Unplug the device immediately after use.
- Never clean the equipment with the machine plugged in.
Unplug the equipment before cleaning.
- The motor unit will remain stable if it is placed vertically on a
work surface.
Any other use than that described in this manual
will not be considered normal by the manufacturer.
Holding the green «+» button item O in for more than1 second
changes the speed directly to maximum.
e) To reduce the speed
Press several times in succession on the black «-» button item
P.
The speed drops by gradual steps with each press on the black
«-» button item P.
Note:
1) A red overload warning lamp item N fl ashes when the appliance
is overloaded: this does not alter the operation of the machine in
any way, but it is preferable to reduce the operating speed to a
point where the warning light goes out. If the speed is not reduced
when the warning lamp fl ashes, the machine continues to operate
correctly but is liable to stop more quickly due to overheating of
the motor; in this case red lamp M remains lit constantly.
The appliance is also protected against overheating that can
happen during prolonged and intensive use. In this case the mixer
stops by itself and the red warning light remains lit constantly, indi-
cating that the stop is due to the appliance thermic safety feature
operating.Unplug the appliance and wait for a few minutes until
the motor cools down; plug it in again, the indicator lamp should
be off. If that is the case, unplug the appliance once more and
wait again until the motor cools down.