START-UP
Minimum power supply requisites and connections:
Electric mains - Single-phase voltage 230V 50/60Hz with grounding wire
ated mm
2
2,5. A circuit breaker must be installed upstream from the electrical soc-
ket 6Ka 30mA 16A.
Compressed air mains - Working pressure not over 8 bar; the mains must supply
dehumidified and filtered air.
OPERATING INSTRUCTIONS
Electrical tool connections
- Insert the tool's plug into the socket (21) on the unit;
- if the tool is equipped with a vacuum device, connect it to the 2-way (30) link
using the sleeve (47);
- do not connect tools with loads over their rated capacity
electrical sockets.
Pneumatic tool connections
- Connect the compressed air hose to the rapid fitting on the unit (20); connect
the other end to the tool;
- if the tool is equipped with a vacuum device, connect it to the 2-way (30) link
using the sleeve (optional) (48).
Preliminary checks
- Check that the dust bag is in the container and that the filter is assembled on the
head;
- check that the vacuum hose is properly fixed and does not hinder tool move-
ment;
- check that there are not leaks from the compressed air supply system.
Only after having performed connections should you proceed with a brief operating
trial of the tools following their instructions.

MACHINE USE

The machine may be operated in automatic or manual mode: select the chosen
mode by turning the unit's switch (22) to the automatic or manual position.
The switch on the dust extractor must always be set within the green area re-
gardless of the chosen mode.
Automatic operations
Automatic operations means that the vacuum starts when an electrical or pneu-
matic tool is turned on. The vacuum will automatically turn off eight seconds af-
ter the tool is turned off.
Manual operations
Manual operations means that the vacuum functions continuously.
TROUBLESHOOTING AND SOLUTION
Effects
The vacuum does not start
The vacuum does not start automatically
Vacuum capacity is insufficient
Dust is discharged from the exhaust
Tools do not start
No compressed air
No compressed air for tools
Power dims when pneumatic tools are connected
MAINTENANCE
The manufacturer or an authorised representative must carry out a technical ope-
rating inspection of the machine controls and check for any damage to the ma-
chine's filtering system at least once a year. RUPES Spa is not liable for any di-
rect or indirect damages due to failure to comply with the instructions provided in
this manual.
Ordinary maintenance (by the user)
- Check the conditions of the vacuum hoses (47-48);
- periodically clean the filter (51) using the cleaning system switch (35)
(fig. 27);
- replace the dust bag (58) as follows:
1. Wear a dust mask in accordance to the law (such as 3M 06922 type);
2. open the door (55) by rotating the knob to the left (fig. 13 and 14);
3. remove the old bag closing the opening with the cap provided (fig. 15 and 16);
4. put the new bag in place inserting the opening in the outlet as illustrated (fig. 17 and
18);
(2x800 W max)
to the
5. close the door and rotate the knob to the right (fig. 20).
Warning!
- By simply opening the door periodically check the bag: maximum capacity is Kg
7 in weight and 50 litres in volume: do not exceed the indicated limit!!
- If the removed bag is torn and dust leaks, check the filter and have replaced if
necessary by an authorised service centre.
- Spare bags should be kept in dry places!
- Only use RUPES dust bags cod. 037.1101/C.
Extraordinary maintenance
(by the authorised service center)
- Periodically check if filters on the cooling or exhaust pipes need replacement;
- periodically check the conditions of electrical wires and plugs; if they are
damaged or worn replace;
- replace the filter (51) if excessively clogged or torn as follows:
1. Wear a dust mask in accordance to the law (such as 3M 06922 type);
2. unhook the vacuum head from the container using the hooks (42) (fig. 21);
3. turn the head upside down and place it on the container (fig. 23);
4. free the filter frame (50) from the head using the metallic clips (49) (fig. 24 and
25);
5. remove the used filter and place it in a bag for disposal (fig. 26);
6. insert the new filter in the frame and assemble the frame to the head;
7. Assemble the head on the container.
Warning!
Only use RUPES filters cod. 021.1106
Causes
No power supply
Power cord, switch or motor defective
Electronic module or micro-switch malfunction
Bag too full
One of the hoses or accessories is clogged
Filter cartridge torn
3-way switch malfunction
Input hose incorrectly connected
Output hose incorrectly connected
Insufficient compressed air feeding
Solutions
Make sure the unit is plugged in
Contact an authorised service centre
Contact an authorised service centre
Check the filtering bag
Check the flexible hose and the accessories
Contact an authorised service centre
Contact an authorised service centre
Check connections
Check connections
Check air passage
11