Step 4: Tighten all KD screws.
Step 5: Carefully move the assembled unit to the desired location. The fireplace
mantel should not be positioned in area exposed to direct sunlight.
WAll ANcHOr SAFEtY cABlE
The use of wall anchor safety cable is highly recommended in order to reduce the
risk of the fireplace being tipped over accidentally.
WARNING: This cable may reduce possible risk of injury if the fireplace is
improperly handled, but is not a substitute for proper adult supervision.
Children should not be left unattended near any heater.
Step 1: Drill a 5/16 in (8 mm) hole in the wall. Insert the plastic wall anchor into the
hole and gently tap until the flange on the anchor is against the wall surface.
Step 2: Position the back edge of the mantel close to the wall.
Step 3: Attach the safety cable to the mantel using the screw for mantel. See Fig. K.
Step 4: Use the screw for wall to attach the other end of safety cable to the wall.
Step 5: Make sure all screws are tight.
OPErAtiON
After reading complete instructions, confirm all controls on fireplace are in the OFF
position. Plug the fireplace into a 15 AMP / 120 Volt outlet. If the cord does not
reach, you may use an extension cord rated for a minimum of 1875 WATTS. Once
the fireplace insert has been properly connected to a grounded electrical outlet, it is
ready to operate.
OPErAtiON BY tHE cONtrOl PANEl
The controls are located behind the grill below the glass and can be accessed by
pulling the grill from the top, forward and down.
WARNING: DO NOT TOUCH. HOT SURFACE AT CENTRE OF GRILL. HOLD LEFT
OR RIGHT SIDE OF THE GRILL WHEN PULLING OUT.
Fig. K
bACk
O/I: Press this button for main power function and flame effect. See below for other
control switches.
1250W: For heat function – Press this switch while the O/I switch is in the ON position.
The indicator light will turn on.
Temperature Control: To adjust the temperature to your individual requirements,
turn the temperature control dial to the right (clockwise) to increase the desired
temperature and to the left for lower temperature. This temperature control dial can
only be used while the O/I switch and 1250W switch are in the ON position. When the
heater reaches the desired temperature, the heater and 1250W indicator light will turn
off but the fan will continue to operate. Adjust this knob to restart the heater.
NOTE: When the O/I switch is turned off, all other heater functions will stop even
though the switches may be in the on position.
NOTE: In order to shut down the heater safely, it is recommended to turn the
temperature control knob to lowest setting and allow the heater to cool down before
press the O/I switch to off position.
MAiNtENANcE
MAINTENANCE: Disconnect power and unplug the power cord before
attempting any maintenance or cleaning to reduce the risk of fire, electric
shock or damage to persons. The bulbs in your unit can become extremely hot.
Allow at least 10 minutes between turning off the unit and removing the light
bulbs to avoid the accidental burning of the skin.
RISK OF FIRE: Do not exceed the recommended bulb wattage.
rEPlAciNG tHE liGHt BUlBS
Step 1: Remove 12 screws on the back of fireplace and open the rear cover.
Step 2: You will find 1x40W type B-10 bulbs under the log-set bed.
Step 3: Loosen and remove the burnt out bulb and replace with new bulb.
Step 4: Close the rear cover. Secure the 2 larger screws into the top left corner hole
and bottom right corner holes as shown in the diagram. Secure the 10 smaller
screws into the remaining holes. Make sure the screws are in the correct holes
and have been tightened.
Step 5: Plug in the unit.