Thank you for purchasing this Price Pfi ster product. All Price Pfi ster products are carefully engineered, and factory tested to
provide long trouble-free use under normal conditions. This product is easy to install using basic tools and our easy to follow
illustrated instructions. If you have any questions regarding this product, call 1-800-Pfaucet (1-800-732-8238).
1 BEFORE PROCEEDING
WARNING: Read all the instructions completely before proceeding. Price Pfi ster
recommends calling a professional if you are uncertain about installing this product!
This product should be installed in accordance with all local and state plumbing and
building codes.
WARNING: This product has been designed for use with the Price Pfi ster 15-3WD
(Not included, order separately) series diverter valve. It will not work with any other
product. Please review the 15-3WD series diverter valve installation instructions before
installing this product.
2 SHUT OFF WATER SUPPLY
Locate water supply inlets and shut off the water supply valves. These are usually
found near the water meter. If you are replacing an existing unit, remove the old unit
and clean the mounting surface thoroughly.
3
3 TOOLS RECOMMENDED
• PTFE plumber's tape or thread sealant
• Adjustable wrench
• Flashlight
Your installation will require a pipe nipple for the spout installation as well as other
additional tools.
4
L
K
F
E
M
C
B
4 CHECKING THE CONTENTS OF THE BOX
Upon opening the box, check to ensure that all of the following items are included.
A Hand Shower
B Hose
D Drop Elbow
E Handle
G Retainer Sleeve
H Washer
K Hex Wrench
L Set Screw
N Anchors (2X)
If any of these items are missing, please contact Price Pfi ster Consumer Service at
1-800-Pfaucet (1-800-732-8238).
• Philips head screwdriver
• Cloth
H
J
G
A
N
D
C Wall Mount
F Extension Stem
J Trim Flange
M Screws (2X)
ENGLISH
5
5E
2.00" Dia
PRIMARY
OUTLET
INLET
5 VALVE LOCATION
Be sure that Diverter Valve Body (5A) is positioned correctly in wall, where the Supply
Valve Shower Outlet is to connected to the Diverter Valve Body Inlet (5B). Be sure that
Primary Outlet (5C) and Secondary Outlet (5D) connections are properly connected.
Center Hole (5E) on wall is 2.00" Dia.
6
6A
6 COVER REMOVAL
Remove Plastic Cover (6A) from Diverter Valve Body (6B).
2
5A
5D
5A
SECONDARY
OUTLET
5C
5B
6B
5D