e l e C t r o n i C r o o m
t h e r m o s t a t
1
i n s tall at i on
Fix the thermostat on the wall, at 1,5 mt height
from the floor and away from the kitchen, heat
sources, windows, doors etc..
remove the body of the thermostat from the
base as shown in the illustration.
turn the cover-plate downwards.
attention: Pay attention that the body of the
thermostat is well fixed on the wall, on a plane
surface and without strains.
2
e l eCt r iC Co nne Ctio ns
Connect the C63 to the power supply and to
the user as shown in the scheme aside. When
the room temperature increases, the relay
opens terminal 1 - 2.
3
i n s e r t th e b atteri es
pay attention to the polarity.
4
F i X th e b oDY onto th e P late
5
s e l eCt io n oF th e oPerati V e
m o D e : W in t er – oF F – s Ummer
the C63 has a switch that allows to choose
the operative mode sUmmer
systems) Winter
and oFF (system oFF).
When the red leD is on, it means that the
batteries have to be replaced with new ones
t e C h ni Cal Ch ar aCteri sti Cs
in compliance with the en 60730-1 and parts two specs
Contact rating 16(4)a 250V ~.
micro-disconnection (1b).
no-load switching contact.
t35 (max room temperature measurable).
setting range 6 to 30°C.
intervention differential 0,5 K.
thermal gradient 4°K/h.
(double insulation).
Pollution degree 2.
e n g l i s h
(for cooling
(for heating systems)
for round flush-mounting box
b 60 mm
a 83,5 mm
for rectangular flush-mounting
box type 503 (three modules)
user *
*pump, burner
(pompa, bruciatore)
temperature knob
regulator
Winter
oFF
sUmmer
switch
Protection degree iP20.
Voltage: nr. 3 class aaa long life alkaline batteries
1,5 V pencil batteries.
max impulse Voltage: 4000V.
max. dissipated power 1Va.
red led showing the low batteries level.
Winter - oFF - sUmmer switch.
erP classification: erP Class I; 1% (eU reg. 811/2013
- 813/2013)
C63
!
Warning! the
thermostat shall
be installed
only by qualified
personnel!
when on,
replace
batteries
3