3.3 Standard
General standards ______________EN 61800-1, IEC 143-1-1.
Safety _______________________EN 50178, UL 508C
Climatic conditions ______________EN 60721-3-3, class 3K3. EN 60068-2-2, test Bd.
Clearance and creepage _________EN 50178, UL508C, UL840. Overvoltage category for mains connected
Vibration _____________________EN 60068-2-6, test Fc.
EMC compatibility ______________EN61800-3/A11, EN 12015
Rated input voltages ____________IEC 60038
Protection degree ______________IP20 according to EN 60529
Approvals _____________________CE.
3.4 Input
Type
ULN AC Input voltage
AC Input frequency
IN AC Input current for continuous service :
@ 230Vac; IEC 146 class 1
@ 400Vac; IEC 146 class 1
@ 460Vac; IEC 146 class 1
Max short circuit power
AGy - Overvoltage threshold (Overvoltage)
AVy - Overvoltage threshold (Overvoltage)
AGy - Undervoltage threshold (Undervoltage)
AVy - Undervoltage threshold (Undervoltage)
Braking IGBT Unit Standard internal (with external
resistor); MAX Braking power (@400V):
• Lift Drive System
circuits: III; degree of pollution 2
Table 3.4.1: Input data
2040
[V]
[Hz]
7
[A]
7.9
[A]
7
[A]
650
[kVA]
440VDC (for 230VAC mains), 820VDC (for 400VAC mains),
[V]
444VDC (for 230VAC mains), 721VDC (for 400VAC mains),
[V]
[V]
230VDC (for 230VAC mains), 380VDC (for 400VAC mains),
225VDC (for 230VAC mains), 392VDC (for 400VAC mains),
[V]
140%
2055
2075
3110
230 V -15% ... 480 V +10%, 3Ph
50/60 Hz ±5%
9.5
14
18.2
10.7
15.8
20.4
9.3
13.8
17.8
850
1200
1700
820VDC (for 460VAC mains)
815VDC (for 460VAC mains)
415VDC (for 460VAC mains)
818VDC (for 460VAC mains)
150%
110%
100%
3150
25
28.2
24.5
2250
130%
tab_3-4