5.2.3 Fuses of the power section
The inverter must be fused on the AC Input side. Use superfast semiconductor fuses only.
Type
2040
2055
2075
3110
AGyL3150
AVyL3150
Fuse manufacturers:
Jean Müller, Eltville = Type GRD... , Z14... 14 x 51 mm, Z22... 22 x 58 mm
Ferraz = A70...
Bussmann = FWP...
5.2.4 EMI filters
All the Lift Drive System models are internally equipped with an external EMI filter in order to reduce
the radiofrequency emissions on to the mains line
5.2.5 Braking Resistors
The braking resistors can be subject to unforeseen overloads due to possible failures.The resistors
have to be protected using thermal protection devices. Such devices do not have to interruptthe circuit
where the resistor is inserted but their auxiliary contact must interrupt the power supply of thedrive
power section. In case the resistor foresees the precence of a protection contact, such contact has
tobe used together with the one belonging to the thermal protection device. Recommended resistors
for use with internal braking unit:
Type
P
NBR
[kW]
[Ohm]
0.
2040
0.
2055 ... 2075
1.
3110
.1
3150
Parameters description:
P
Nominal power of the braking resistor
NBR
R
Braking resistor value
BR
E
Max surge energy which can be dissipated by the resistor
BR
5.2.6 Cooling fan
No connection is required, the internal fan is power supplied by an internal circuit.
230 ... 400 Vac, 50Hz
GRD/1 or Z14GR1
GRD/0 or Z14GR0
GRD/5 or Z14GR5
GRD/50 or ZGR40
GRD/50 or ZGR50
ZGR
R
E
Resistor
BR
BR
[kJ]
Type
100
22
MRI/T600 100R
68
MRI/T900 68R
4
48
MRI/T1300 49R
28
0
BR T2K0-28R
Fuses
A0P0
A0P0
A0P5
A0P5
A0P40
A0P0
Dimensions : mm (inch)
Weight
kg (lbs)
length
heigth
1.5 (.)
0 (1.)
10 (4.)
. (.0)
0 (1.)
10 (.)
. (.)
0 (1.)
0 (1.)
5.4 (.)
4 (1.)
100 (.)
460 Vac, 60Hz
FWP0
FWP0
FWP5
FWP5
FWP40
FWP0
tab5
depth
fix 1
fix 2
100 (.)
0 (14.)
-
10 (4.)
0 (15.0)
-
10 (4.)
0 (15.0)
-
50 (.)
4 (1.)
40 (1.)
tab55
Lift Drive System • 4