security
Made in Italy
BT2014/35/UE
EMC2014/30/UE
Double element pyroelectric sensor (Digipyro™).
Sensor microwave 10,525Ghz.
Complete of anti-disorientation articulated joint
Adjustable sensibility with trimmer.
Antiopening protection tamper.
Anti sabotage function.
Anti-masking function.
High immunity RF 30Vm.
Power supply voltage 12V.
Max current consumption20mA.
Beams of the lens23 (on 3 horizontal levels).
Coverage angle frontal (PIR) H: 120°; V: 60°.
Coverage angle of the microwave H: 80°; V: 32°.
Coverage 12mt.
Signalling LED.
Solid state NC 100mA, 50Vdc max. relay outputs.
Initial stabilizing time 30".
Safety degree: 1.
Ambiental class: 2.
Dimensions (WxHxD) 59x99x60mm.
Approved directives CEI EN 50131-1
INSTALLATION
Remove the ellettronic circuit from the container, leveraging laterally with a tool and engage the joint at the base of
the container after passing through the fixing ring.
Use the extension cable for the hub in case of ceiling mounting.
Cover the unused hole on the bottom of the container with the supplied carpet
Secure the base of the ball on a smooth , flat and vibration free, covering
the hole for the passage of electrical cables for connection to the central,
using the brackets provided.
Pass the cables through the hole in the hinge and hook the locking ring at
the base.
Once installed and oriented in the desired position , it will be possible to lock
the detector rotating at the bottom of the lock ring.
Replace the circuit board on the bottom of the container and provide the
connections.
Is possible to mount the detector at an angle (in this case do not use the
joint, but drill two holes in the container for mounting on the sides
Don't direct the detector toward objects that could produce rapid starts of
temperature as heaters, electric radiators, air conditioners, free flames, etc.
To also avoid the installation in proximity of them.
Not partially or completely obscure the field of vision of the detector.
Make connections according to the diagram on next page.
ATTENTION Do not touch with finger the pyroelectric sensor
:
EXAMPLES OF INSTALLATION
Installation to angle
Utilize DG12 base only
Lead free
Pb
DG12 - Dual Technology Detector: passive infrared and microwave
RoHS
compliant
.
Wall mounting
is done using the joint cable supplied
where it is possible to orient it with
horizontal and vertical adjustments.
Installing block joint
Insert the lock into the hole
by passing the cables inside
(even with the ceiling mount)
Ring locking
Ceiling Installation
is done using the extension of the
joint present within the package.
DG12
Pextension
for installation
ceiling