OPERATION
The DG12 works in "dual technology", which means that only if both technologies (Infrared and Microwave) reveal a
real intrusion alarm is given.
This allows to avoid only the forgeries due alarms to the activation of the sensor to infrared (at times caused to es.
from the rays of the sun) or of the only microwaves sensor (at times caused to es. from objects in movement).
ANTI MASKING
The DG12 if they continue or alarm of one of the two technologies, and in the absence of the other
rilevazionje, activates a state of continual alarm, indicated by the flashing red LED and the contact area of
open country that still does not resume until both technologies to function properly.
In this way, if you mask for example, the infrared sensor thermal isolation, but it continues to alarm sensor
repeatedly to microwave oven, the detector is placed in a state of continuous alarm that triggers the alarm of
the central alarm.
ANTISABOTAGE
If the DG12 detects a presence very close to the detector (about 40cm) is placed in a state of continual alarm,
indicated by the flashing of the red LED and the opening of the contact zone.
Even in this case, if after a few seconds, both technologies resume detect presences at a greater distance,
and therefore are normally operating, the detector resumes its normal operation.
Operation LED
Green LED ON : Microwave sensor activated
Yellow LED ON: Infrared sensor activated
Red LED ON: Detector in Alarm
Red LEd Flashing: alarm detectors in continuous anitimanomissione / Antimask
Red LED flashing slowly: Time to initial stabilization
Make connections according to the diagram below.
BURGLAR ALARM
4
Horizontal sight
*
0
GND in
-
-
-
GND
Chiave
12Vcc
IMM
RIT
Tamper
anti-opening
Microwave
section
Vertical sight
2m
0
12m
other
outputs
of the
in
+
+
-
Int
-
24h
12V
system
to 24h
DG12
*
12m
3
6
only microwave
*
GND in
GND in
-
-
-
-
in
in
IMM
RIT
IMM
RIT
Pyroelectric
sensor
+
Trimmer
sensitivity adjustment
infrared microwave