or vertically, provided that the water flow is from bottom to top (see schematic diagram at the
beginning of the instructions for use), with 30 cm of unobstructed space on the side opposite the
lamp connection for future maintenance. At least one metre of unobstructed space must be left
on the side with the lamp connection for convenient future replacement of the lamp (K) without
having to disconnect the entire device.
CAUTION: All connections and couplings must be hand-tight. Do not tighten them with tools.
Otherwise damage may occur.
1. Unscrew the nut (N) from the housing (U). Remove the UV-C lamp (K) from the supplied tube
(see packaging) and carefully slide the lamp into the quartz sleeve (M). Place the lamp (K) with
the contact pins in the lamp fitting (L) and then tighten the nut (N) on the housing (U).
2. Fit the supplied pipe clamps (O). Then insert the unit into the pipe clamps. Tighten the three-
piece coupling (I) firmly, while ensuring the correct position of the sealing rings (P), both at the
connections and the quartz sleeve (see figure 2).
3. Mount the unit in the circuit by means of the three-piece coupling (I) and the glue coupling for
the flow switch (V *For amalgam only). The glue connections of the three-piece coupling are
Ø63 mm or 2". If the pipes are smaller than Ø63 mm or 2", use the Ø63 x 50 mm (T) or 2" x 1.5"
x 1" adapter. This can be glued in the three-piece coupling (I) and in the glue coupling for the
flow switch (V *For amalgam only). The inside of the adapter (T) has internal screw threads at
one end, making it possible to fit a hose tail adapter (not included) with sealing ring.
4. Insert the plug of the UV-C device into an earthed wall socket that is protected by a residual
current device.
5. Look through the transparent parts of the device to make sure the lamp is lit.
6. The device is shut off when power is disconnected from the device.
*For amalgam only
7. The glue coupling for the flow switch (V) must be positioned on the three-piece coupling (I)
with the screw thread (W) facing up (see figure 2). The glue coupling (V) can be glued to a
three-piece coupling (I). Mount the flow switch (X) which is attached to the electrical section
(S) directly to the screw thread (U) of the glue coupling (V) (see figure 2). If the flow switch is
mounted differently, the device will not work. The arrow on top of the flow switch (X) must
always point in the direction of water flow. If it points in the direction opposite the water flow,
the UV-C device will remain off.
8. When no water is flowing through the device, the flow switch automatically switches the unit
off.
INSTRUCTIONS FOR USE OF THE DIGITAL TIME METER
As soon as the UV-C device is switched on, the program will carry out a self-test. The display will
automatically show the following , one after the other: 8888 (display test) ; r and software version
UV-C 75W/130W AMALGAM MANUAL |
EN
7