KX15DTAM
15m - 90° Dual Technology Anti-Mask
Detector
EN50131-2-4:2008
EN50131-1:2006+A1:2009
Security Grade (SG) 3
Environmental Class (EC) II
References
Anti-Masking: The KX15DTAM uses the patented Anti-Masking technology to
detect when both PIR and Microwave technologies are Masked. The detector is
able to detect aluminium foil, spray and any object position on or in front of
the detector with the purpose of obstructing the field of view of the PIR or MW
sensors.
The Mask is adjustable between 0 to 1M.
If the Masking area is entered the Blue LED starts flashing to show that the
area has been compromised. If the obstacle is removed after 30 seconds the
detector will reset to normal. If the obstacle still remains after 1 minute, the
MASK and ALARM relay will open and the Green and Orange LEDs will be
permanently activated. To reset the detector, the obstacle must be removed
and a walk test must be done.
Blocking: This feature is to detect a partial obstruction of the PIR up to
15m when the panel is disarmed. When blocking is detected the alarm relay
will open and the GREEN and ORANGE LEDs will be activated. To reset the
blocking, the KX15DTAM must be walk tested so that the PIR and MW sensors
are activated.
Blocking Enabled/Disabled: To enable the feature, switch 6 must be OFF
and the RI input should be connected to an output on the control panel which
gives 0V when DISARMED and removes 0V when ARMED.
KX15DTAM is supplied with the following:
KXBRACKETW (Wall Bracket), KXBRACKETC (Ceiling Bracket) and K-TAMPER
(Back tamper)
Other Wiring Diagrams
NOTE: When the 2 optional lenses are used the Microwave range
remains at 15m.
Technical Specification
Casing: White, 3mm polycarbonate, 0.4mm HDPE in Lens Area
Lenses: 15m Volumetric fitted. 18m Curtain and 30m Long Range lens supplied.
LED Colours: Orange (Microwave), Blue (Alarm, Mask), Green (PIR).
Sensitivity Selectable: AUTO or Pulse Count 1
Temperature Compensation: Digital
Detection Speed: 0.25 - 2.5m/s
Detection Range: 15m (13m according to EN50131-2-4).
Operating Voltage: 9-16VDC, 13.8VDC typically
Relay Output: 50mA 60VDC, 42 VAC (RMS)
Current Consumption: 24mA Min. 30mA Max @ 12V
Contact Resistance: <10 Ω
Mounting Height & Range: 1.8m - 3m (best place 2.4 m)
Tamper Switch: 12VDC 50mA both front and rear
Storage Temperature: -40°C to +80°C
Certified Temperature: -10°C to +40°C
Operating Temperature: -30°C to +70°C
Dimensions & Weight: 117 x 69 x 50mm, 125g without bracket
Emissions EN55022 Class 2. Immunity EN50130-4
Proctection against EMI and RF
NOTE 1: The mask adjustment needs to be set to half way to comply with
EN50131-2-4. NOTE 2: Do not partially or completely obscure the detector's field of
view with large objects such as furniture.
!
This product operates in a European non-harmonised
frequency band
Frequencies Countries
9.9Ghz
AT, BE, CH, CY, CZ,
DK, FI, FR, GR, HU, IE,
IS, IT, LT, MT, NL, PL,
SI, TR
10.525Ghz
BE, CH, CY, DK, HU,
IE, IS, IT, MT, NL, NO,
SE, SI
10.587Ghz
GB
Warranty
This product is sold subject to our standard warranty conditions and is warranted against defects in
workmanship for a period of five years. In the interest of continuing improvement of quality, customer
care and design, Pyronix Ltd reserves the right to amend specifications, without prior notice.
Visit www.pyronix.com/warranty for more information.
Product Warning Information
For electrical products sold within the European Community. At the end of the electrical
products life, it should not be disposed of with household waste. Please recycle where
facilities exist. Check with your Local Authority or retailer for recycling advice in your
country. This product operates in a European non-harmonised frequency band. Hereby
Pyronix declares that this detector is in compliance with the essential requirements and other
relevant provisions of Directive 1999/5/EC. The declaration of conformity may be consulted
at www.pyronix.com/product-compliance.php
This product is approved for use in the Residential,
Commercial and Light Industrial Environment.
 0845 6434 999 (UK). +44(0)1709 535 225
START
3
3EOL
A
A
T
T
EOL INPUT 1
1M
MAX
Max: 1M
30% Mask
≤1m
 customer.support@pyronix.com
MASK/ALARM EOL
LINK
2
DEOL
N/C
A
A
T
T
A
A
T
T
EOL INPUT 1
EOL INPUT 1
30%
OFF
>1m
 www.pyronix.com
OFF
2
DEOL
A
A
T
T
EOL INPUT 1
10.515GHz
10.525GHz
10.525GHz
10.525GHz
Pyronix Limited, Pyronix House, Braithwell Way, Hellaby, Rotherham, S66 8QY, UK
N/C
A
A
T
T
EOL INPUT 1

Publicidad

loading

Resumen de contenidos para Pyronix KX15DTAM

  • Página 1 LINK will open and the GREEN and ORANGE LEDs will be activated. To reset the blocking, the KX15DTAM must be walk tested so that the PIR and MW sensors are activated. Blocking Enabled/Disabled: To enable the feature, switch 6 must be OFF and the RI input should be connected to an output on the control panel which gives 0V when DISARMED and removes 0V when ARMED.
  • Página 2 Horizontal Coverage at Maximum Range 0.25 - 2.5m/s 0.25 - 2.5m/s Vertical Coverage Vertical Coverage Vertical Coverage  0845 6434 999 (UK). +44(0)1709 535 225  customer.support@pyronix.com  www.pyronix.com Pyronix Limited, Pyronix House, Braithwell Way, Hellaby, Rotherham, S66 8QY, UK...
  • Página 3 Z1 COM Z1 COM Z1 COM 60 zones 7 planes RLNS074 INCERT ONLY Volumetric Lens VERTICAL COVERAGE 1.8-2M  0845 6434 999 (UK). +44(0)1709 535 225  customer.support@pyronix.com  www.pyronix.com Pyronix Limited, Pyronix House, Braithwell Way, Hellaby, Rotherham, S66 8QY, UK...
  • Página 4 GROENE en ORANJE LED geactiveerd. Als u de blokkering opnieuw wilt orangefarbene LED aktiviert. Um den KX15DTAM zurückzusetzen, muss ein Gehtest un essai de marche doit être exécuté sur le KX15DTAM de manière à ce que les la funzione di ostruzione, KX15DTAM deve essere sottoposto al test di passaggio, instellen, moet de KX15DTAM een looptest doorlopen om de PIR- en MW-sensoren te durchgeführt werden, damit die PIR- und MW-Sensoren wieder aktiviert werden.
  • Página 5 охраны. При обнаружении блокирования размыкается реле сигнализации и el bloqueo, el KX15DTAM tiene que realizar pruebas de movimiento para activar a função de obstrução, o KX15DTAM deve ser submetido a um teste de 15 m po rozbrojeniu alarmu. Po wykryciu blokady nastąpi otwarcie przekaźnika активируются...