Command devices
Stop button ((N.C.) contact.)
Gate stop button with exclusion of automatic closing, to
resume movement press command button or transmitter
button.
If unused, short-circuit contact 1-2.
if unused
Radio and/or button contact for commanding
Radio and/or button contact for commanding ( (N.O. contact
- Command button (see selecting features, DIP-switch 2).
- Command button (see selecting features, DIP-switch 2).
Safety devices
C1 = (N.C.) contact di riapertura durante la chiusura»
Input for safety devices like photocells, sensitive edges
and other devices that comply with EN 12978 regula-
tions. While the door is closing, opening the contact
will invert movement until it is fully openend.
If unused, short-circuit contact 2-C1.
if unused
C1 = (N.C.) contact di riapertura durante la chiusura»
N.O. contact) )
RX
RX
DIR
Delta-S
Delta-S
TX
TX