Event History - Ingersoll Rand Schlage P516-486 Instrucciones De Instalación

Tabla de contenido

Publicidad

3
Enroll the Sensor
a. Press and release the "+" button on the Bridge. The orange LED will blink slowly to indicate enrollment mode.
The Bridge will remain in enrollment mode for 30 seconds before timeout.
b. Use a pin or paper clip to press the program button on the back of the Sensor case.
c. During enrollment, the Bridge's LED will change from slow to rapid blinking.
d. When enrollment is successful, the Bridge's orange LED will light solid, and the Sensor's LED will turn off.
e. If the Bridge LED never blinks rapidly and enrollment mode times out (after 30 seconds), and the Sensor's LED does not turn off, then
repeat step a–d.
a.
Orange LED
+ Button
4
Verify the Motion Sensor is added to the Nexia Bridge
! Remove the 9-volt battery from the Nexia Bridge, if installed.
a. Connect the Bridge to AC power and to your router (Ethernet).
b. Login to your online Nexia account.
c. Click on "Security & Sensors", then "Sensors", then "Setup Device". (See Figures 1 – 3 below.)
SECURITY &
SENSORS
CAMERAS
LIGHTING &
MODULES
CLIMATE
Figure 1
5
Test Tamper Indication (Optional)
• If the Sensor's cover is removed, the Sensor's LED will light solid for up to ten (10) seconds, and a "tamper condition" message will be sent
to the Nexia Bridge.
• Check that the tamper condition is indicated on the Nexia portal online display. (Refer to the example below.)

Event History

Date
Time
02/15/2012
12:00 PM
02/15/2012
11:30 AM
Note: Browser feedback is not immediate. The online display may take 5 seconds to 1 minute to change. Be sure to allow time for the browser
to refresh.
b.
Security & Sensors
New Sensor
Sensors
Locks
Sensor Type
Alerts
Motion Sensor
Alert when motion detected
Save Changes
NO MOTION DETECTED
Figure 2
Figure 3
Filter by: Show All
User
Device
New Sensor 4
New Sensor 4
Motion
s
s
C
Cancel
Event
Tamper Alarm
Closed