6
Determine Motion Sensor Placement
• Place the Sensor so that the detection zone will cover the area to be monitored. (Refer to coverage diagram below.)
• Do not install the Sensor on a metal wall.
• Do not install the Sensor in a location where large metal objects (i.e., kitchen appliances) may limit the wireless signal.
• Avoid placing the Sensor in a location that is facing direct sunlight, where the temperature may change rapidly, or where air ducts or other
considerable airfl ow is nearby.
Note: An optional Schlage Z-Wave repeater (RP100, RP200) can improve performance.
7
Install the Mounting Bracket and Motion Sensor
! Install the Sensor 6¹⁄₂ to 7¹⁄₂ feet (2 to 2.3 meters) above the fl oor.
! Mounting Bracket may be installed using either adhesive tape or screws (included). Follow steps for the preferred method:
Install Mounting Bracket with screws
Attach the Mounting Bracket to the wall using four screws (included) when mounted against a corner, or with two screws (included) when
mounted against a fl at surface.
OR with adhesive tape
Attach the Mounting Bracket to the wall using a strip of double-sided adhesive tape (included). Note: Extended use of double-sided tape
may damage paint or wall material.
Install the Sensor
Align holes on the back of Sensor with tabs on Mounting Bracket. Push down on Sensor to secure it to the Mounting Bracket.
4 screws
Solid areas on the diagram (above, right) represent positive detection capability.
5
8
Motion Sensor Test and Operation
The Sensor detects motion and sends a status to the Nexia Portal. (The Sensor is not intended to operate as a Z-Wave repeater.)
Before normal use, verify proper operation of the Motion Sensor.
a. Clear the motion detection zone for 4 minutes.
b. Move in the coverage area. Check that the LED on the Motion Sensor blinks once.
c. When motion is detected, a message is sent to the Nexia Bridge and the Sensor remains in an active state until no further motion occurs
for a period of 4 minutes. Any motion detected before 4 minutes will cause the timer to reset for another 4 minutes. (Motion reset time may
be changed for test purposes. See Maintenance for more information.)
d. Check that the Nexia portal indicates motion was detected with "motion detected" message.
e. After 4 minutes with no motion detected, the Sensor will return to normal operation, and transmit a "no motion detected" message.
f. Check that the Nexia portal indicates "no motion detected".