FUNCTIONAL DESCRIPTION
CAUTION:
Always be sure that the tool is switched off and the
•
battery cartridge is removed before adjusting or
checking function on the tool.
Installing or removing battery cartridge
1
2
014905
CAUTION:
Always switch off the tool before installing or
•
removing of the battery cartridge.
Hold the tool and the battery cartridge firmly
•
when installing or removing battery cartridge.
Failure to hold the tool and the battery cartridge
firmly may cause them to slip off your hands and
result in damage to the tool and battery cartridge
and a personal injury.
To remove the battery cartridge, slide it from the tool
while sliding the button on the front of the cartridge.
To install the battery cartridge, align the tongue on the
battery cartridge with the groove in the housing and slip
it into place. Install it all the way until it locks in place
with a little click. If you can see the red indicator on the
upper side of the button, it is not locked completely.
CAUTION:
Always install the battery cartridge fully until the
•
red indicator cannot be seen. If not, it may
accidentally fall out of the tool, causing injury to
you or someone around you.
Do not install the battery cartridge forcibly. If the
•
cartridge does not slide in easily, it is not being
inserted correctly.
Tool /battery protection system
The tool is equipped with a battery protection system.
This system automatically cuts off power to the motor to
extend battery life.
The tool will automatically stop during operation if the
tool and/or battery are placed under one of the following
conditions:
1. Button
2. Red indicator
3. Battery cartridge
3
Overloaded:
•
The tool is operated in a manner that causes
it to draw an abnormally high current.
In this situation, turn the tool off and stop the
application that caused the tool to become
overloaded. Then turn the tool on to restart.
If the tool does not start, the battery is
overheated. In this situation, let the battery
cool before turning the tool on again.
Low battery voltage:
•
The remaining battery capacity is too low
and the tool will not operate. In this situation,
remove and recharge the battery.
Overheat protection for tool/ battery
When the tool/ battery is overheated, the tool stops
automatically without any indication. The tool does not
start even if turning the tool on. In this situation, let the
tool/ battery cool before turning the tool on again.
NOTE:
The battery overheat protection works only with a
battery cartridge with a star marking.
1
012128
Indication lamp with multi function
014906
Indication lamps are located in two positions.
When the battery cartridge is installed on the tool with
the slide switch positioned in the "O (OFF)" position, the
indication lamp flickers quickly for approximately one
second. If it does not flicker so, the battery cartridge or
indication lamp has broken.
Overload protection
−
When the tool is overloaded, the indication lamp
lights up. When the load on the tool is reduced,
the lamp goes out.
5
1. Star marking
1. Indication lamp
1