2
Mount to Wall
2-1
Locate studs
< 16 mm
(5/8 in.)
2-2
Mark the wall
2-3
Drill pilot holes
2-4
Tighten lag bolts
[01]
[05]
[04]
6
Wood stud
406 mm
(16 in.)
[01]
Verify the center of the stud(s) using an awl, a thin nail, or an edge to edge
stud fi nder.
CAUTION:
Avoid potential personal injuries and property damage!
Any material covering the wall must not exceed 16 mm (5/8 in.).
Minimum wood stud size: common 51 x 102 mm (2 x 4 in.) (nominal
38 x 89 mm (1.5 x 3.5 in.)).
Minimum horizontal space between fasteners: 406 mm (16 in.).
Level the wall plate [01] and mark the hole locations.
CAUTION:
Avoid potential injuries or property damage! Pilot
holes MUST be drilled to a depth of 75 mm (3 in.), using a 5.5 mm
(7/32 in.) diameter drill bit.
CAUTION:
Avoid potential injuries or property damage!
Improper use could reduce the holding power of the lag bolt. To
avoid potential injuries or property damage
DO NOT over-tighten the lag bolts [04].
Tighten the lag bolts [04] only until the washers [05] are
pulled fi rmly against the wall plate [01].
13 mm
(1/2 in.)
(7/32 in.)
75 mm
(3 in.)
6910-002038 <01>
5.5mm