Electrical Installation - STEINEL LS 300 S Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
LS 300 S product components (Fig� 3�8)
A
LED panel
B
Enclosure
C
Wall mount
Technical specifications
– Dimensions (H × W × D):
LS 300 S: 241 × 213 × 186 mm
LS 300: 218 × 213 × 184 mm
– Power consumption (P
– Luminous flux (120°):
– Half-way angle:
– Efficiency:
– Power supply:
– Colour temperature:
– Average rated life expectancy:
L70B50 at 25°C: 36,000 hours
– Colour rendering index:
– Colour consistency SDCM:
– Luminous intensity distribution:
– Area illuminated to the front:
– Sensor technology (S onlyS):
– Sensor on standby (P
– Angle of coverage (S only):
240° with 180° angle of aperture
– Sensor unit swivelling range (S only):
– Floodlight adjusting range:
– Time setting (S only):
– Twilight setting (S only):
– Reach (S only):
– Mounting height (S only):
– IP rating:
– Protection class:
– Ambient temperature:
4� Electrical installation
Connection
The supply lead is a 2 or 3-core cable:
L = phase conductor (usually black, brown or grey)
N = neutral conductor (usually blue)
PE = protective-earth conductor (green / yellow)
Note:
The protective-earth conductor need not be con-
nected for this product.
):
29.50 W
on
2704 lm
92 lm/W
220 – 240 V, 50/60 Hz
4000 K (neutral white)
R
starting value 6
LumEdit
202007061517_LS300_MIT_SENSOR_NW.LDT
150°
180°
120°
90°
60°
30°
C0 / C180
cd / 1000 lm
355 cm²
20.04.21 / 15:23
passive infrared
) (S only):
0.50 W
sb
turns through ± 40°
vertically + 110° to -40°
10 s - 15 min
2 - 1000 lux
max. 12 m
1.8 - 2 m
-10 °C to +30 °C
Wiring diagram (Fig� 4�1)
The light source of this LED floodlight cannot be
replaced. If the light source needs to be replaced
(e.g. at the end of its service life), the complete LED
floodlight must be replaced.
51°
5� Installation
Hazard from electrical power�
= 80
a
Polar Diagram
Touching live parts can result in electrical shock,
150°
burns or death.
120°
• Switch OFF power and interrupt power supply.
90°
100
• Using a voltage tester, check to make sure the
200
60°
300
light is disconnected from the power supply.
400
30°
C90 / C270
• Make sure power supply remains interrupted.
1/1
Risk of damage to property!
Mixing up connection leads may produce a short
circuit.
• Identify connection leads.
± 80°
• Re-connect connection leads.
Preparing for installation
• Check all components for damage. Do not use
the product if it is damaged.
• Select an appropriate site to install the product.
– Take reach into consideration. (Fig� 5�1)
– Take reach and motion detection into consid-
eration. (Fig� 5�2, 5�3)
IP44
– Vibration-free.
I
– No obstacles in detection zone.
– Not in explosive atmospheres.
– Not on normally flammable surfaces.
– Do not look into the LED light from a short
distance (<20 cm).
– Installing LED floodlight in horizontal
position (± 15°).
• Correctly aiming LED floodlight. (Fig� 5�4)
Mounting procedure
• Check to make sure the power supply is
switched OFF. (Fig� 4�1)
• Detach plug-in terminal from wall mount.
(Fig� 5�5)
• Mark drill holes. (Fig� 5�6)
• Drill holes and fit ground plugs. (Fig� 5�7)
– 14 –

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ls 300

Tabla de contenido