Product components (Fig� 3�3)
A Load module, power supply lead, surface-mounted
B Load module, power supply lead, concealed installation
C Designer trim, round or square
D Sensor module
Product dimensions
Ceiling / wall mounting / surface-mounted and concealed wiring (Fig� 3�4)
4� Electrical installation
The supply lead consist of three wires:
L
= phase conductor (usually black, brown or grey)
N = neutral conductor (usually blue)
PE = protective-earth conductor (green/yellow)
Wiring example (Fig� 4�1)
– Surface-mounted installation
If the rubber seal is damaged, the cable entry openings must be sealed with an M16
or M20 (at least IP54) double seal cable gland.
For mounting on the wall, a condensation water drainage hole (Ø 5 mm drill bit) is
marked next to the rubber seal. This must be opened if necessary. (Fig� 5�3)
An optional corner wall mount is available for mounting the HF 3360 DALI
(Prod. No. 035174 white).
Master/slave (Fig� 4�2)
The HF 3360 DALI is suitable for use in master/slave networks. In this case, the DALI
sensor is the master, the LiveLink sensor the slave.
The master/slave configuration permits detection of movement in larger rooms or
spaces (load connected = master, no load = slave). The level of brightness prevailing
in the room is only evaluated at the master. The slaves report movements detected to
the master. Lighting is only switched ON and OFF by the master.
As many as 30 users can be connected.
5� Mounting
• Check all components for damage.
• Do not use the product if it is damaged.
• Select an appropriate mounting location, taking the reach and
motion detection into consideration.
22
Installation procedure
Wall-mounting, concealed power supply lead (Fig� 5�1)
Ceiling mounting, concealed power supply lead (Fig� 5�2)
Wall-mounting, surface-mounted power supply lead (Fig� 5�3)
Ceiling mounting, surface-mounted power supply lead (Fig� 5�4)
• Switch OFF power supply.
• Detach designer trim from sensor module.
• Disconnect sensor module from the load module.
• Connect to mains power supply.
- Surface-mounted power supply lead (Fig� 5�5)
- Concealed power supply lead (Fig� 5�6)
• Insert fastening screw and mount load module.
• Fit sensor and load module together and screw into place.
• Switch ON power supply.
• Set functions. (➔ "6� Function")
• Fit designer trim.
6� Function / operation
Factory settings
Twilight level:
1000 lux
Reach adjustment: approx. 1 m
Time setting:
5 s
Main light:
80%
Constant light
Provides a constant level of brightness. The detector measures the prevailing level
of daylight and activates sufficient artificial light to achieve the required level of
brightness. As daylight changes, the added artificial lighting component is adjusted.
In addition to the daylight component, artificial light is also switched ON and OFF in
relation to whether or not persons are present.
Constant-lighting control can be activated / deactivated via RC8 remote control and
Smart Remote.
Twilight setting (Fig� 6�1)
The chosen sensor response threshold is infinitely adjustable from approx. 2 to
1000 lux.
Control dial set to
means twilight mode at approx. 2 lux.
Control dial set to
means daylight operation / independent of ambient light level.
Teach mode
The control must be set to
at the level of light at which you want the sensor to
respond to movement from now on. The level of ambient brightness measured in this
way will be saved after 10 seconds.
23