GE SmartWater GXWH01C Instrucciones De Instalación página 3

Ocultar thumbs Ver también para SmartWater GXWH01C:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Select Location
Select a location for the filter that is:
I
protected from freezing.
I
not exposed to direct sunlight.
Install Fittings
Instructions are for installing fittings supplied with the
filter (on some models) or the WHKIT onto 3/4" copper
plumbing. If the unit is to be installed on any other type of
tubing (plastic, PVC, galvanized), different hardware must be
purchased. See instructions with additional hardware
purchased, or consult a qualified plumber.
Apply about 6" of Teflon
®
the pipe threads (course) of each adapter. DO NOT use joint
compound on any parts.
Cut Water Line
Turn off water supply and open a nearby faucet to drain
1
water out of pipes.
Remove the nut and brass ferrule from both compression
2
fittings and set aside. Using a tape measure or ruler,
measure the distance "D" as shown.
I
NOTE: It is recommended that the shut-off valve be placed
before and after the filter as shown in the Installation
Overview illustration.
I
Select the location for the filter. Mark the distance "D"
on the pipe.
Attach Fittings to Water Line
Slip a compression nut onto each pipe.
1
Next, slip the brass ferrule onto each pipe.
2
Installing the Unit
Align filter assembly with pipe ends making certain that the
1
incoming water supply is going into the filter opening marked
"IN" . It may be necessary to spread the pipe ends apart to install
filter assembly.
Installing the Ground Wire
IMPORTANT: A copper or galvanized house cold water pipe is often
used to ground electrical outlets in the home. Grounding protects you
from electrical shock. The water filter housing may have broken this
ground path. To restore connection, install a 12" long, 8-gauge
copper wire across the filter, tightly clamped using UL-approved
1/2"–1" bronze grounding clamps at both ends as shown. Zinc
clamps should not be used on copper plumbing. For GXWH01C,
wire and clamps may be purchased separately from your local
hardware store, or are available by visiting our Website at
www.GEAppliances.com, or from Parts and Accessories by calling
800.626.2002 (U.S.)or 800.663.6060 (Canada) – order part
number WHKIT.
Final Check
Install filter, if not all ready done. (See Filter Cartridge
1
Replacement section.)
Slowly turn on water supply.
2
Check entire system for leaks.
3
STEP-BY-STEP INSTALLATION INSTRUCTIONS (cont.)
tape, in a clockwise direction, to
It is recommended that a shut-off valve be placed on both sides
of the filter.
Assemble an adapter to the inlet and outlet of the head.
Start each fitting by hand to make sure they don't cross
" wrench firmly. DO NOT OVERTIGHTEN.
1
thread. Use a 1
8
About one to two thread(s) should remain visible.
Teflon
®
tape
Using a pipe cutter or hacksaw, cut pipe. Sand (file) cut
3
ends of pipe to assure that they are square and smooth.
GXWH01C
D
Brass ferrule
Nut
" wrench to hold the adapter in place, use a 1
Using a 1
1
2
8
wrench to tighten the nut. Repeat process for other fittings.
If necessary, support the water pipe on either side of the filter
3
unit.
Clean copper pipe and ends of wire with emery paper. Bare wire
1
is recommended. If insulated wire is used, it should be stripped
3/4" at each end before cleaning with emery paper.
Attach bronze clamps to copper pipe. Tighten screws.
2
Attach wire to clamps as shown. Tighten screws.
3
NOTE: If your house plumbing is plastic, it would not be used as a
grounding path, and this step should be skipped.
If leaking, shut off water pressure and tighten or reseal
4
fittings.
Open any downstream faucet and allow filter system to
5
flush for 5 minutes.
3
GXWH08C
Measure to shoulder
of fittings. Copper
pipe butts against
this shoulder.
D
Brass ferrule
Nut
Ground wire
Clamp
D
"
1
4

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Smartwater gxwh08c

Tabla de contenido