Heavy-Duty Water Filtration Unit—GXWH40L (filters not included)
Check with your state and local public works department for
plumbing and sanitation codes. You must follow these guidelines
as you install the Heavy-Duty Water Filtration Housing. Using a
qualified installer is recommended.
Be sure the water supply conforms with the Performance Data .
If the water supply conditions are unknown, contact your
municipal water company.
This Heavy-Duty Water Filtration Housing must be properly installed and located in accordance with the Installation
Instructions before it is used.
Check with your local public works department for plumbing codes.
You must follow their guides as you install the Heavy-Duty Water
Filtration Housing.
Use the Heavy-Duty Water Filtration Housing on a potable, safe-to-
drink, home COLD water supply only. The filter cartridge will not
purify water or make unsafe water safe to drink. DO NOT use on
HOT water (100
°
F max).
Protect the Heavy-Duty Water Filtration Housing and piping from
freezing. Water freezing in the housing will damage it.
Your Heavy-Duty Water Filtration Housing will withstand up to 100
psi water pressure. If your house water supply pressure is higher
than 100 psi during the day (it may reach higher levels at night),
install a pressure-reducing valve before the housing is installed.
REQUIRED TOOLS AND ACCESSORIES
FOR INSTALLATION
■ 2 Adjustable wrenches
■ Pipe cutter
■ Ruler or tape measure
■ Cordless drill
■ File
■ Emery paper
■ Screwdriver
■ Additional installation parts may be required:
• 2 fittings to connect household plumbing to 1" female NPTF
threads on filter housing
• UL-approved grounding clamps and 6-gauge copper
grounding wire
• Teflon tape
INSTALLATION INSTRUCTIONS
SAFETY PRECAUTIONS
PROPER INSTALLATION
184D1061P003
GENERAL ELECTRIC COMPANY, Appliance Park, Louisville, KY 40225
GE
WARNING:
microbiologically unsafe or of unknown quality without adequate
disinfection before or after the system.
It is highly recommended that a water shut-off valve be placed
directly upstream of your household filter.
Do not install on HOT WATER . The temperature of the water
supply to the Heavy-Duty Water Filtration Housing must be
between the minimum of 40°F and the maximum of 100°F.
See the Performance Data section.
Do not install the Heavy-Duty Water Filtration Housing using
copper solder fittings. The heat from the soldering process
will damage the unit.
WARNING:
material after installation. Small parts remaining after installation
could be a choke hazard.
Do not install filter in an outside location or anywhere it will be
exposed to sunlight.
Optional accessories are available (Visa, MasterCard or Discover cards
accepted) by visiting our Website at GEAppliances.com or from Parts and
Accessories, call 800.626.2002 (U.S.) or 800.663.6060 (Canada).
CONTENTS INCLUDED WITH PRODUCT
■ Filter housing and head
■ Product literature
■ Canister wrench
■ Timer and batteries
■ Mounting bracket
■ 4 Hex-head screws and 4 Hex washer-head screws
GXWH40L is Tested and Certified by NSF International
against NSF/ANSI Standard 42 with cartridge FXHTC
for the reduction of Chlorine, Taste and Odor.
49-50220-3
(04-09 JR)
GEAppliances.com
1
Do not use with water that is
Discard all unused parts and packaging

Publicidad

Tabla de contenido
loading

Resumen de contenidos para GE GXWH40L

  • Página 1 ■ 4 Hex-head screws and 4 Hex washer-head screws threads on filter housing • UL-approved grounding clamps and 6-gauge copper GXWH40L is Tested and Certified by NSF International grounding wire against NSF/ANSI Standard 42 with cartridge FXHTC • Teflon tape for the reduction of Chlorine, Taste and Odor.
  • Página 2: Typical Installation

    Control handle Inspect the filter canister O-ring. Make sure it is lightly lubricated with clean food-grade silicone grease (silicone Red pressure- release button grease is available through GE Parts and Service: Head 1.800.626.2002, part number WS60S10005). Be sure the Filter cartridge O-ring is seated in the groove.
  • Página 3: Final Check

    STEP-BY-STEP INSTALLATION INSTRUCTIONS (cont.) ■ not exposed to direct sunlight. Select Location Select a location for the filter that is: It is recommended that a shut-off valve be placed on both sides of the filter. ■ protected from freezing. It is recommended that a mounting bracket be used. Cut Water Line ■...
  • Página 4: Parts List

    Timer Installation and Reset Instructions Blue reset button Timer battery installation and change Installation of timer Insert coin or screwdriver in the slot between timer Hold the timer body in the center and gently push Timer cap cap and base. Gently pry them open and separate time timer to its seat at the top of the head.
  • Página 5: Mesures De Sécurité

    INSTRUCTIONS D’INSTALLATION Unité de filtration d’eau pour service rigoureux—GXWH40L (filtres non inclus) MESURES DE SÉCURITÉ ■ Consulter le service local des travaux publics au sujet des codes de AVERTISSEMENT : plomberie et de raccordement aux égouts. L’installation du logement Ne pas utiliser ce produit de filtration d’eau pour service rigoureux doit être conforme aux...
  • Página 6: Spécifications De Cartouche

    (vous trouverez la graisse de silicone au service de pièces et d’entretien GE, en téléphonant au 1.800.626.2002, numéro de Tête Cartouche pièce WS60S10005). Assurez-vous que le joint torique repose bien de filtration dans le sillon.
  • Página 7: Installation Du Filtre

    Fixez le fil sur les attaches comme indiqué. Serrez les vis. maison. Cette mise à la masse vous protège contre les chocs électriques et cette liaison à la terre peut voir été neutralisée par le logement du filtre d’eau. Pour Conducteur de liaison rétablir la connexion, montez un fil en cuivre de 18 po et de calibre 6 le long du...
  • Página 8: Liste Des Pièces

    Installation de la minuterie et instructions de réglage Installation et remplacement de la pile de la minuterie Installation de la minuterie Bouton bleu de remise à zéro Insérez une pièce ou un tournevis entre le capuchon de Tenez la minuterie de au centre et poussez doucement Capuchon de minuterie et sa base.
  • Página 9: Unidad De Filtración De Agua Extrafuerte-Gxwh40L (Filtros No Incluidos)

    INSTRUCCIONES DE INSTALACION Unidad de filtración de agua extrafuerte—GXWH40L (filtros no incluidos) PRECAUCIONES DE SEGURIDAD ■ Consulte con su departamento de obras públicas local y estatal para ADVERTENCIA: los códigos de plomería y sanidad. Usted debe seguir estas reglas a No use con agua que sea medida que instale el alojamiento de filtración de agua extrafuerte.
  • Página 10: Especificaciones Del Cartucho

    (la para reducir grasa de silicona está disponible a través del departamento de Partes la presión y Servicio de GE llamando al 1.800.626.2002, número de parte Cabeza Cartucho WS60S10005). Cerciórese de que el aro tórico es asentado en la del filtro ranura.
  • Página 11: Seleccione La Ubicación

    INSTRUCCIONES DE INSTALACION PASO A PASO (cont.) Seleccione la ubicación Se recomienda instalar una válvula de cierre en ambos lados del filtro. Seleccione una ubicación para el filtro que esté: Sugerimos que se utilice una ménsula de instalación. ■ protegida de la congelación. ■...
  • Página 12: Lista De Partes

    Instalacion del cronometro e instrucciones de reinicialización Instalación y cambio de las baterías del cronómetro Instalación del cronómetro Botón de reajuste azul Inserte una moneda o un destornillador en la ranura entre Sostenga el cuerpo del cronómetro en el centro y Tapa del cronómetro la tapa y la base del sincronizador.

Tabla de contenido