DeWalt DCC018 Manual Del Usuario página 33

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
nOTE: The light will not time out until the entire unit times out.
OPERATION
Instructions for Use

WARNING: Always observe the safety instructions and
applicable regulations.

WARNING: To reduce the risk of serious personal
injury, turn tool off and disconnect battery pack
or external power supply before making any
adjustments or removing/installing attachments or
accessories. An accidental start-up can cause injury.
Switching On (Fig. A)

WARNING: Risk of Bursting. Do not leave unit running
unattended. Over inflation of tyres and other items could
result in serious injury and property damage.
nOTE: When power is supplied to the inflator by 12V vehicle
connector, 18V battery or an external power supply (optional
accessory), the LCD display will remain on for approximately
2 minutes before the display shuts off/goes into sleep mode.
This occurs when the unit is not operating. To wake up the
system, press the power switch 
on and the inflator is ready for use.
Before switching your inflator on, decide which power source
you will be using; a 18V battery pack 
connector 
 19 
, or an external power supply (optional accessory),
and connect them using the following instructions. You can
then press the AC/DC power switch 
the unit.
Powering with an 18V Battery Pack
To use the 18V battery pack, refer to Inserting and Removing
the Battery Pack.
Powering with the 12V DC Vehicle Connector
To use the 12V DC vehicle connector 
vehicle's 12V DC accessory socket. Always fully extend the
12V DC cord before each use. Your vehicle's accessory socket
must be rated for at least 12A.
Powering with an External Power Supply (Fig. C)

WARNING: Use only the external power supply
recommended for this product. Use of any other
external power supply could damage the inflator or
power supply.
To use an external power supply, attach the DC output cord
from the external power supply to the external power supply
connector 
 20 
on the side of the unit, then plug the 220V–240V
AC cord end into the wall outlet or an appropriate-sized
extension cord that is plugged into a wall outlet. Always fully
extend the cord before each use.
To Inflate/Deflate Using High-Volume
(Fig. A, B)
The high-volume hose is meant to be used for objects that hold
large amounts of air, such as air mattresses, rafts, and swimming
pool floats.
 2 
. At this time the LCD will turn
 12 
, the12V DC vehicle
 2 
located on the front of
 19 
, connect it to your
nOTE: The high-volume mode DOES NOT have an auto shut-
off feature.
To Inflate
1. Remove the high-volume hose 
Attach the high-volume hose to the high-volume outlet/
inflation port 
as described in the Fitting the High-
 18 
Volume Hose section.
2. Insert the high-volume hose 
into the object being inflated.
3. Press the power switch 
.
 2 
4. Then press the pressure mode switch. You will see the
inflator/deflator symbol in the pressure setting/mode
display 
.
 8 
5. Then press the inflation start/pause button 
pump on.
6. To turn off, press the inflation start/pause button 
To Deflate
Follow steps 1 through 6 in section To Inflate above, but attach
the high-volume hose to the inlet/deflation port 
To Inflate Using High-Pressure (Fig. A, B)

WARNING: Risk of Bursting. Excessive air pressure may
cause a hazardous risk of bursting or personal injury.
Check the manufacturer's maximum pressure rating for
items being inflated.

WARNING: Replacing the high-pressure hose must be
done by a D
WALT service organisation.
e
The high-pressure hose 
 10 
is meant to be used for objects that
need more air pressure, such as tyres and basketballs.
1. Remove the high-pressure hose 
storage channel.
2. Attach a nozzle as described in the Fitting the Accessories
section. Attach the chuck to the tyre stem to inflate a tyre, or
attach an accessory to inflate a ball or other inflatable.
3. Attach or insert the nozzle into the object being inflated.
4. Press the power switch 
. The inflator will default to High-
 2 
Pressure inflation mode.
nOTE: The pressure gauge display 
pressures when the inflator is in high-pressure mode.
nOTE: To switch between units, press and hold the inflation
mode switch 
 3 
and the LED light switch 
the pressure adjustment knob 
5. Rotate the pressure adjustment knob 
desired pressure.
6. Press the inflation start/pause button 
7. To stop the inflator at any time, press the inflation start/pause
button 
 7 
.
8. When the item to be inflated has reached the preset value,
the unit will automatically turn off.
nOTE: You may notice the actual pressure reading may
drop after a couple of seconds. This is normal.
nOTE: If the power switch 
 2 
is turned off, all settings will be
lost and will need to be reentered. This is a safety feature to
prevent the risk of items OVER INFLATING.
EnGLIsH
 5 
from it's storage channel.
 5 
, or its tapered nozzle 
 13 
 7 
to turn the
 7 
.
 14 
, Fig. A.
 10 
from its
 9 
will only show inflation
 4 
while rotating
 6 
.
 6 
to set the
 7 
to begin inflation.
31

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

566405.0100

Tabla de contenido