9.6
Conectando Red de Computadora Evolution
PCB 169
N.C.
N.C.
N.O.
N.O.
IN
OUT
IN
OUT
Auxilliary Alarm
Open
Close
Open
Close
Open
Close
Close
Close
Com.
Com.
+12V
U1
U1
U2
AUX
Com
Aux.
Aux.
U2
AUX
Auxilliary Inputs
Relay Control
Tunnel Aux. Input
Natural Ventilation Module
White
White
White
White
White
Black
Black
Black
Black
Black
Shield
Shield
Shield
Shield
Shield
Sensor #1
Sensor #2 Sensor #3 Sensor #4
Sensor #5 Sensor #6
9.7
Conectando Dispositivo de Alarma al Evolution
PCB 169
N.C.
N.C.
N.O.
N.O.
IN
OUT
IN
OUT
Auxilliary Alarm
Close
Open
Close
Close
Open
Open
Close
Com.
Com.
U1
AUX
Com
Aux.
Aux.
+12V
U1
U2
U2
Auxilliary Inputs
Relay Control
Tunnel Aux. Input
Natural Ventilation Module
White
White
White
White
Black
Black
Black
Black
Black
Shield
Shield
Shield
Shield
Sensor #1
Sensor #2 Sensor #3 Sensor #4
Sensor #5 Sensor #6
NOTA: La escritura interna muestra las condiciones del relay
durante condiciones normales (Alarma no presente).
Durante una alarma, la posición del contacto estará al revés.
Parte No. 4801-5332 Rev 01-15
L1
+12V +5V
L2
AC Supply
DC Power Supply
Open
Close
Open
Close
-
-
Open
Close
AUX Com
+12V
U2
AUX
U1
U1
U2
Vent Aux. Input
Relay Control
Var #1
Var #2
Variable Module
Power Ventilation Module
HHNet Termination
White
White
White
White
-
Black
Black
Black
Black
+12V
GND Shield
Shield
Shield
Shield
Shield
Sensor #7
Sensor #8
Outside
Local Network
+12V +5V
L1
L2
DC Power Supply
AC Supply
Close
Close
-
-
Open
Close
Open
Close
Open
AUX Com
AUX
U2
AUX
+12V
U1
U1
U2
Vent Aux. Input
Relay Control
Var #1
Var #2
Power Ventilation Module
Variable Module
HHNet Termination
White
White
White
White
White
Black
Black
Black
Black
-
Shield
Shield
Shield
Shield
Shield
+12V
GND Shield
Sensor #7
Sensor #8
Outside
Local Network
Evolution 3000 y 3001
3000 & 3001
¡ADVERTENCIA!
¡BAJO VOLTAGE!
¡Mantenga separado de los
cables de alto Voltage!
Recuadro A
Twisted Pair
Cables Enrollados
Cable
3000 & 3001
Recuadro A
Recuadro A
Cambiar posiciones
N.C.
IN
Auxiliary Alarm
Para conectar las
alarmas en serie.
Recuadro A
¡ADVERTENCIA
¡VOLTAGE BAJO!
¡Mantenga separado de los
cables de Alto Voltaje!
N.O.
N.O.
N.C.
OUT
IN
OUT
Para conectar
alarmas
paralelamente
Pagina 42 de 62
!