Descargar Imprimir esta página

Instruction Sheet - Vimar Eikon 20140 Hoja De Instalación

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
Eikon
Plana
20140
14140
20141
14141
20140 - 14140
230 V~ dimmer for incandescent lamps 40-700 W at 50/60 Hz, ferromagnetic trans-
formers 40-700 VA, control and regulation with built-in button or from several positions
with N.O. buttons, MASTER function for 20141 and 14141, MOSFET+TRIAC technol-
ogy, identification in the dark, protection fuse, grey - 2 modules
20141 - 14141
230 V~ SLAVE dimmer for incandescent lamps 40-700 W at 50/60 Hz, ferromagnetic
transformers 40-700 VA, control from 20140 and 14141, MOSFET+TRIAC technol-
ogy, protection fuse, grey - 2 modules
Characteristics
• SLAVE dimmers need MASTER dimmers to function.
• Lighting, adjusting and turning off with incorporated buttons or normal N.O. buttons
without pilot light.
• Lighting level is saved when turned off (unless there is a blackout).
• Soft start: ensures gradual lighting from zero to maximum or preset lighting levels.
This way the life of a lamp is increased by reducing stress on the filament and
prevents light flash.
• Soft end: ensures a gradual passage from light to dark.
• Fuse with high breaking capacity type F5AH (07050.HF.5) incorporated.
• Overheating protection with flashing blowout detector.
• MASTER-SLAVE function: paying attention not to exceed maximum power control-
lable by each dimmer, a MASTER device can have up to 4 SLAVE devices added.
• It should be used in dry, dust-free places at a temperature between -5 °C and
+45 °C.
Connections
• Control and dimming with incorporated button or several points with NO buttons in
parallel (figure A). Do not use NO buttons with pilot light.
• Control and adjustment with incorporated button + control and adjustment of fur-
ther loads using the SLAVE support module (max 4) (figure B).
Note.
• Loads controlled by each device are not parallel in the MASTER-SLAVE function.
• Maximum length of cables connecting MASTER dimmer and SLAVE dimmer: 100
metres.
Controllable loads
• Incandescent and halogen lamps: 40-700 W 230 V~ 50/60 Hz.
• Ferromagnetic transformers for low-voltage halogen lamps: 40-700 VA 230 V~
50/60 Hz.
WARNING: The above power data are guaranteed at an ambient temperature of
25°C; for each increase of 10°C in the ambient temperature, the power value must
be reduced by 10%.
A
L
N
20140
14140
Viale Vicenza, 14 - I 36063 Marostica VI
Tel. +39.0424.488.600 - Fax: (Export) +39.0424.488.709
www.vimar.eu
Constructor further information
• Not suitable to control motors (e.g. ventialtors and exhaust fans).
• For installation with 2 dimmers in the same mounting box, the loads controllable
by each dimmer should be reduced so that theri total does not exceed the values
indicated above.
Operating
• Turn on and off by pressing the button quickly and make adjustments by keeping it
pressed. Stop and restart to change direction.
When maximum or minimum load is reached, dimming stops and can be inverted
by pressing the dimmer again.
• If the pilot light does not turn on check the fuse and if necessary replace it with the
same model.
• If the pilot light flashes after turning on, installation has not been carried out correctly
and the overheating protection has been activated. Have the system checked by
an expert.
Installation regulations
• The installation should be carried out in compliance with current electrical installa-
tion regulations in the country where installed.
• The rated power level should never be exceeded.
• Overloading, power surges and short-circuits may permanently damage dim-
mers. Before installation check the circuit carefully and eliminate any of the above
causes.
• Do not connect several dimmers in series between each other.
• The dimmer does not have a mechanical circuit breaker in the main circuit and so is
not galvanically separated. The circuit load should be considered always under
voltage.
B
L
N
20140
14140
In order to function correctly the length of each connection between the MASTER dimmer and
SLAVE dimmer or NO buttons should not exceed 100 m.
Characteristics of
Controllable
controllable
loads
transformer
20141
14141
ENGLISH

Instruction sheet

20140
20141
14140
14141
MASTER
SLAVE
40 - 700 W
40 - 700 W
40 - 700 VA
40 - 700 VA
It is recommended to position the connection con-
ductors on the bottom of the box avoiding contact
with the body of the dimmer.

Publicidad

loading

Este manual también es adecuado para:

Eikon 20141Plana 14140Plana 14141Eikon 20140.nPlana 14140.slEikon 20141.n