3. INSTALLATION INSTRUCTIONS

1. Carry the device to the place of installation and remove it from its
package.
2. Check whether the device is in a solid state. If there is damage,
immediately notify this situation to your dealer and if you have any
doubt do not operate the device without having it checked by an
expert.
3. Peel away the protective nylon on the device. If there are material
remains left on the surface, clean them with a convenient dissolver.
(For Example; Henkel-Helios)
4. If possible, place the device near a water connection and waste
water drain.

4. WATER CONNECTION

1. Connect your device to the city water normally. However, you can
also connect it to the hot water input in order to save electricity.
2. Perform the connection between the device and the tap with the
provided flexible hose.
3. In order for the device to work correctly, the input water must be at
7 Fr hardness and min 2 bar, max 4 bar pressure.
4. Do not use old or used water inlet hose at the new product.
WARNING:
Drain pipe required to be connected to a drain at height 50 mm from ground for base model
devices and at max. 700 mm from the ground for the devices with pump to maintain a reliable
water flow.
For longer life and efficiency of your device, attach a lime remover at the water input. Otherwise the lime
scale that will accumulate at the internal surfaces of the boiler and pump will prevent the device from
working efficiently.
For your safety, you must turn off the water inlet tap at the end of the washing program.

5. POWER CONNECTION

1. The installation and power connection of the device must be performed by authorized personnel according
to the standards.
2. The device needs to be connected to a network which is consistent with the DIN VDE 0100 power installment
standards.
3. Usage of a H07 RN-F quality 3x2,5mm2 profile cable is necessary for the power connector line.
4. The device needs to be connected to a master switch (contact distance 3mm or more) and to a fused isolator.
5. Voltage tolerance ± must not go over % 10.
6. A maximum of 25A fuse must be put to the device feed line.
7. We recommend the usage of a 30 mA faulty residual current device.
8. The device must absolutely be grounded. For this, DIN VDE 0100 clause 540 must be taken into consideration.
Grounding screw is indicated at the bottom left section with the "
WARNING:
Don't make connections with extension cords or multi sockets. A damaged power cable must be changed by the
Authorized Service. Our firm is not responsible for any damage which may occur in case of its use with an earthing
which is incompatible with local regulations.