2.
Lift and turn the coil support plate according to the
nail length to be used.
► 1. Coil support plate 2. Graduation
Nail length
57 mm or 65 mm
(2-1/4" or 2-1/2")
45mm or 50mm
(1-3/4" - 2")
38 mm
(1-1/2")
3.
Place the nail coil over the coil support plate.
Uncoil enough nails to reach the feed claw. Place the
first nail in the driver channel and the second nail in the
feed claw. Place other uncoiled nails on feeder body.
Check if the nail coil properly set in the magazine and
then close the magazine cap and the door.
► 1. Feed Claw
1
2
Position of coil support
plate
Bottom step
Middle step
Top step
1
Connecting air hose
CAUTION:
Do not rest your finger on the
trigger when connecting the air hose.
► 1. Air fitting 2. Air socket
Slip the air socket of the air hose onto the air fitting on
the tool. Be sure that the air socket locks firmly into
position when installed onto the air fitting.
A hose coupling must be installed on or near the tool in
such a way that the pressure reservoir will discharge at
the time the air supply coupling is disconnected.
OPERATION
CAUTION:
Make sure all safety systems are in
working order before operation.
Selecting the operation mode
CAUTION:
Always make sure that the actua-
tion mode selector is properly set to the position
for the desired nailing mode before nailing.
1
► 1. Actuation mode selector
Single sequential actuation mode:
You can drive one nail by one sequential operation. Select
this mode when driving a nail carefully and accurately.
To choose this mode, set the actuation mode selector to
the
position.
8 ENGLISH
1