Customising A Timer Programme; Calibrating The Room Sensor - De Dietrich CDI4 Instrucciones De Instalación, Utilización Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 72
3. Operating instructions
EN
+
MODE
%
0
2
4
6
8
10
12
$
MODE
C002393-C
1
2
3
1
2
%
0
2
4
6
8
$
MODE
C002436-A
%
$
+
38
2"
A000858-A
14
16
18
20
22
24
4
5
6
7
3
4
5
6
7
10
12
14
16
18
20
22
24
3x
5"
C002430-A
3.2.2.

Customising a timer programme

CAUTION
P r : Function available depending on the model of control
panel.
Only the timer programmes P2, P3, P4 and the domestic hot water
programme P r can be modified.
1. Press the MODE and r keys simultaneously for 2 seconds. The
time is displayed.
2. Turn the rotary button to select the timer programme to be
modified. To confirm, press the rotary button.
To go back to the previous display, press the key r.
3. All of the days flash. The new programme will be active every day
of the week.
To modify the programme for a particular day, press the rotary button
several times until the desired day flashes.
4. Turn the rotary button to the left until 0.00 is displayed. The first
segment of the graphic bar for the timer programme flashes.
5. b : Comfort mode selection
Press the Cx key. The symbol b is steady, the selection mode for
the comfort time ranges is active.
To select a comfort time range, turn the rotary button to the right.
The zone selected is displayed under b on the graphic bar.
v : Reduced mode selection
Press the Cm key. The symbol v is steady, the selection mode for
the reduced time ranges is active.
To select a reduced time range, turn the rotary button to the right.
The zone selected is displayed under v on the graphic bar.
6. To return to the principal display, press the MODE key or wait 20
seconds.
3.2.3.

Calibrating the room sensor

1. Measure the room temperature with a thermometer.
2. Press key Cx and Vm simultaneously for 5 seconds.
The symbol CAL and the current temperature are displayed.
AD254 - AD285
27/06/2012 - 300020537-001-02

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ad254Ad285

Tabla de contenido