Electronic control for roller shutter with slat orientation and relay outputs for motor
cosφ0.6 2 A 230 V~, can be activated locally or from different points with elec-
tronic remote controls, to be completed with Eikon Tactil cover plate and label.
FEATURES.
• Rated supply voltage: 230 V~, 50/60 Hz
• Relay output: 4 A 230 V~
• Roller shutter control: adjustable from 1 s to 5 min
• Slat control: minimum 100 msec
• Indicator lights with interchangeable symbols for identification in the dark.
• Touch button recalibration: 1 minute
• Operating temperature: -5 °C - +35 °C.
CONTROLLABLE LOADS.
• Resistive loads
: 4 A.
• Motors
: 2 A cos
0.6.
OPERATION.
• Opening and closing roller shutters with:
- two touch buttons on the front;
- control from multiple points using remote control 21122 (maximum distance 100 m);
- two configuration buttons located under the cover plate.
• The touch buttons feature customizable luminous indicators with symbols.
• Top button LED  roller shutter/slat 
• Bottom button LED  roller shutter/slat 
• Long press: enabling roller shutter control
• Short press: cutting off roller shutter control
• Short press with roller shutter stopped: enabling slat control
• The buzzer is always enabled when configuring
N.B: In the event of a mains power failure the device's relay will always go onto NO.
Each time the cover plate is installed, wait at least 1 min. for it to be recalibrated.
CONFIGURATION.
With the device switched off, press both buttons under the cover plate simultaneously. The top
button will start blinking and enter configuration phase 1:
- tap on the bottom button to change the settings of the selected configuration
- tap on the blinking top button to save the selected phase and move on to the next phase of
configuration.
If no operations are performed within 15 s, the device will exit the configuration without saving
the last phase.
SETTING
CONFIGURATION
Top button LED
PHASE 1
Change brightness
1 repeated blink
PHASE 2
2 repeated
Enable buzzer
blinks
PHASE 3
Change
3 repeated blinks
timing
roller shutters
LED on
LED blinking
INSTRUCTIONS.
Connect the appliance as indicated in the "CONNECTIONS" illustration. The power circuits (L-N)
should be protected against overloading by installing a device, fuse or circuit breaker, with rated
current not exceeding 10 A.
INSTALLATION RULES.
Installation should be carried out in compliance with the current regulations regarding the installation
of electrical systems in the country where the products are installed.
• The device can be installed on Eikon Tactil cover plates with 2, 3 and 4 modules; use the dedicated
blank module art. 21041 to close the unused modules.
49400574B0 02 1702
PROCEDURE
Bottom button LED
Press the bottom button
to change the brightness
Always on
cyclically (low, medium,
at the set brightness
high)
Press the bottom button
Buzzer off
to switch the buzzer
on/off
Buzzer on
Press the bottom button
to start the timer; when the
Initially off
lower LED is on and the
desired time has elapsed,
press the top button
Start of timer
to save the timing and
exit the configuration
procedure.
LED off (default)
FRONT AND REAR VIEW
LED
top
button
LED
bottom
button
CONNECTIONS
L
N
For all details on possible installation architectures, please refer to SI-Installation Diagrams for the
relevant item code at www.vimar.com -> Products -> Product catalogue.
INSTALLATION
1.
3.
• When installing with a BS 5M cover plate (2+blank+2), thus on the mounting frame art.
20609, the device cannot be installed in the central module of the mounting frame; this
module should be closed by using the blank module art. 21041 (for details, see SC-Card on
www.vimar.com -> Products -> Product Catalogue at the article code).
• On the same cover plate used for art. 21174 it is not possible to install SELV Tactil devices
(art. 21520, 21540, 21840, 21860).
REGULATORY COMPLIANCE.
LV directive.
EMC directive.
Standard EN 60669-2-1.
P
N
L
L
M
N/O push-button
2.
4.
Viale Vicenza, 14
36063 Marostica VI - Italy
www.vimar.com