Adjusting the detection zone
The detection zone can be limited to suit requirements.
The shrouds supplied with the light can be used to mask
out as many lens segments as you wish. This prevents
the light from being activated unintentionally, e.g. by
cars, passers-by etc., and allows you to target danger
Manual override function
If a mains switch is installed in the mains supply lead,
the light is capable of the following functions in addition
to the simple ON/OFF function:
Sensor operation
1) Switch light ON (when light is OFF):
Turn switch OFF and ON once.
Light stays ON for the period selected.
2) Switch light OFF (when light is ON):
Turn switch OFF and ON once.
The light goes out or switches over to sensor mode.
Technical specifications
Output:
1 x TC-DEL 26 watts
Additional switching capacity:
max. resistive load of 300 W (max. of 5 additional L 360/361 plan lights)
Voltage:
230 – 240 V/50 Hz
Angle of coverage:
360° with 90° angle of aperture and sneak-by guard
Sensor reach:
8 m max. all round
Time setting:
5 sec. – 15 min.
Twilight setting:
2 – 2000 lux
Programme setting:
+
Twilight operation
1
2
Twilight operation to the middle of the night, then sensor-operated mode
3
4
Sensor mode
Manual override:
selectable (4 hours) provided
switch is connected in mains supply lead
Enclosure:
IP 44 (splashproof)
Temperature ranging from:
- 20° C to + 50° C
Operation / Maintenance
The SensorLight is suitable for switching light ON auto-
matically. Weather conditions may affect the way the
SensorLight functions. Strong gusts of wind, snow, rain
or hail may cause the light to come ON when it is not
wanted because the sensor is unable to distinguish sud-
Declaration of conformity
This product complies with the European Directive
on Low-Voltage Appliances, 2006/95 EC and the
spots. The shrouds can be cut along the pre-grooved
vertical divisions. Then you simply clip them onto the
lens.
Manual override
1) Activate manual override:
Turn switch OFF and ON twice. The light is set to stay
ON for 4 hours (red LED lights up behind lens). Then it
returns automatically to sensor mode (red LED OFF).
2) Deactivate manual override:
Turn switch OFF and ON once. The light goes out or
switches over to sensor mode.
Important:
The switch should be actuated in rapid succession
(in the 0.5 – 1 sec. range).
at
Tip!
least
5 min.
den changes of temperature from sources of heat.
The detector lens may be cleaned with a damp cloth
if it gets dirty (do not use cleaning agents).
EMC Directive 2004/108 EC.
PK Elektronik Vertriebs GmbH, E-Mail: info@pkelektronik.com, Internet: www.pkelektronik.com
- 12 -

Troubleshooting

Malfunction
Cause
SensorLight without power
Fuse faulty, not switched ON,
break in wiring
Short circuit
SensorLight will not switch ON
Twilight control set to night-time
during daytime operation
Bulb faulty
Power switch OFF
Fuse faulty
Detection zone not properly
targeted
Internal electrical fuse has
been activated
(red LED flashing rapidly)
Mains terminal not connected
properly
SensorLight will not switch OFF
Continued movement within
the detection zone
Sensor unit is not properly
engaged
SensorLight switching ON when
Wind is moving trees and bushes
it should not
in the detection zone
Cars in the street are being
detected
Sudden temperature change due
to weather (wind, rain, snow) or air
expelled from fans, open
windows
Change in SensorLight reach
Differing ambient temperatures
Red LED flashing rapidly
Internal fuse activated
Functional Warranty
This STEINEL product has been manufactured with
great care, tested for proper operation and safety in
accordance with applicable regulations and then sub-
jected to random sample inspection. STEINEL guaran-
tees that it is in perfect condition and proper working
order. The warranty period is 36 months, starting on the
date of sale to the consumer. We will remedy defects
caused by material flaws or manufacturing faults. The
warranty will be met by repair or replacement at our own
discretion. The warranty shall not cover damage to wear
parts, damage or defects caused by improper treatment
or maintenance. Further consequential damage to exter-
nal items is excluded.
Remedy
Fit new fuse; switch ON mains
switch; check wiring with voltage
tester
Check connections
Re-adjust (control
)
Change bulb
Switch ON
New fuse, check connection if
necessary
Re-adjust
Switch SensorLight OFF and back
ON again after 5 sec.
Firmly press terminal together
Check detection zone and
re-adjust if necessary
Lightly press sensor unit to clip
it into place
Change detection zone
Change detection zone
Change detection zone,
change site of installation
Use shrouds to define detection
zone precisely
Switch SensorLight OFF and back
ON again after 5 sec.
Claims under warranty shall only be accepted if the
product is sent fully assembled and well packed com-
plete with a brief description of the fault, a receipt or
invoice (date of purchase and dealer's stamp) to the
appropriate service centre.
Repair Service:
Our Customer Service Department will
repair faults not covered by warranty or
after the warranty period. Please send
the product well packed to your nearest
Service Centre.
- 13 -

Publicidad

Tabla de contenido
loading

Tabla de contenido