Troubleshooting - STEINEL Studioline IS 2180-2 Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 49
All manuals and user guides at all-guides.com

Troubleshooting

Malfunction
IS 2180-2
without power
IS 2180-2 will not switch
on
IS 2180-2 will not switch
off
IS 2180-2 keeps switching
ON/OFF
IS 2180-2 switches on
when it should not
Cause
a
Fuse faulty; not switched
ON
Short circuit
a
a
Mains switch OFF
Twilight control set to
a
nighttime mode during
daytime operation
a
Bulb faulty
Mains power switch OFF
a
Fuse faulty
a
Detection zone not
a
properly targeted
a
Continuous movement in
the detection zone
a
Light is in detection zone
and keeps switching on
as a result of tempera-
ture change
Set to continuous
a
operation by indoor
series switch
a
Light is in detection
zone
Animals moving in
a
detection zone
a
Heat source (e.g.
extractor hood outlet) in
detection zone
Wind is moving trees
a
and bushes in the
detection zone
a
Cars in the street are
being detected
Sudden temperature
a
changes due to weather
(wind, rain, snow) or air
expelled from fans or
open windows
Remedy
a
Renew fuse, switch on
mains power switch,
check wiring with voltage
tester
Check connections
a
a
Switch on
Adjust setting
a
a
Change light bulb
Switch on
a
Renew fuse, check
a
connection if necessary
Re-adjust
a
a
Check detection zone
and re-adjust if
necessary or fit shrouds
a
Re-adjust zone or apply
shroud
Set series switch to
a
automatic mode
a
Adjust detection zone or
fit shrouds, increase
distance
Adjust detection zone or
a
fit shrouds
a
Adjust detection zone or
fit shrouds
Blank off sections using
a
shrouds
a
Blank off sections using
shrouds
Adjust detection zone or
a
change site of
installation
19

Publicidad

Tabla de contenido
loading

Tabla de contenido