HAEGER FC-326.005A Instrucciones De Uso página 6

Ventilador de techo
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

English
Security Measures
Do not install the fan in damp rooms (bathrooms etc.)
Use the product only in inhabited areas not subject to moisture.
Do not fix the unit to wet surfaces (painted) or metal surfaces that can
conduct electricity.
The location of appliance must allow a secure connection to the power
supply.
For fixing only screws must be used (do not use wire or other materials).
Keep a minimum distance of 2.3m between floor and
ceiling fan and 60cm of the walls.
The electrical system must comply with local regulations.
To avoid the risk of electric shock, connect the grounding fan
appropriately.
Be careful when working in the vicinity of the fan blades in operation.
IMPORTANT. During installation and maintenance of the appliance switch
off main power. It is not enough merely to turn off the switch.
Ensure that there are no current pipes or wires behind the mounting points.
Steps to follow for assembly and installation of fan
1. Carefully unpack your ceiling fan to avoid damage to the fan parts.
Check for any shipping damage to the motor or fan blades. If one of the
fan blades was damaged in shipment, return all the blades for
replacement.
2. Lead the wires emerging from your ceiling through the opening in the
mounting plate. Screw the mounting plate to the ceiling. Make sure the
mounting plate is mounted firmly enough to hold a minimum weight of
23kg.
3. Hang the ball joint and the fan onto the bracket. Make sure the guide pin
of bracket is fitted into slot of ball joint. You should feel the guide pin setting
into the slot of the ball joint.
4. Connect the wires to the terminal block on the mounting plate in the
following way:
Brown or black wire → L
Blue wire → Neutral N
Green/yellow wire → ground
4
Instructions for use

Publicidad

Tabla de contenido
loading

Tabla de contenido