R-134a
4.2

Analysis module not recognised

If the "Refrigerant Test" menu item is not displayed, the
AirConServiceCenter did not recognise the analysis module.
Then proceed as follows:
1. Press STOP to switch to the standby menu.
2. Press the C button.
✓ If the analysis module is recognised, the following display message is
shown:
If the AirConServiceCenter still does not recognise the analysis module,
proceed as follows:
1. Remove the plug from the analysis module.
2. Check the plug's pin assignment.
3. Insert plug.
Ensure that the plug fits into place completely.
4. Press STOP to switch to the standby menu.
5. Wait 1 min.
Restart the refrigerant analysis (chapter "Refrigerant analysis" on
page 12).
EN
R e f r i g e r a n t g .
P A G O i l
m l
U V T r a c e r
m l
1 1 : 5 6 : 3 5
1 0 / 0 3 / 1 8
P S = m b .
2 7
T E M P = 2 1 °
G a s a n a l y s e r O K
X X X X
XXX
XXX
Operation