5 . I N S T A L L A T I O N A N D O P E R A T I O N
1. Checking
NOTE: Before the installation of the unit, please inspect it. Be sure that nothing inside the
package is damaged. Please keep the original package in a safe place for future use.
Packaging includes:
UPS unit, integrated input power cord and user guide.
2. Charging the batteries
This unit is shipped from the factory with its internal battery fully charged, however, some
charge may be lost during shipping and the battery should be recharged prior to use. Plug
the unit into an appropriate power supply and allow the UPS to charge fully by leaving it
plugged-in, with no load, for at least 8 hours.
The UPS will automatically recharge its own batteries whenever the switch is in the "ON"
position. You may use the UPS immediately, however the back-up power capacity may be
lower than the nominal value required.
3. Placement & storage conditions
The UPS has been designed to operate in a protected environment, at temperatures
between 0°C and 40°C and at a humidity level ranging between 0% and 90% (no
condensation).
Do not obstruct the ventilation slots. Install the unit in an environment which is free from
dust, chemical vapours and conductors. Moreover, in order to avoid any interference, keep
the UPS at least 20cm away from the CPU (central processing unit).
4. Connection
Check the identification plate at the back of the UPS to make sure that the power supply is
compatible with network voltage and that the device is powerful enough to protect the given
load. Plug the UPS into a 2-pole, earthed outlet. Then, connect computer-related devices to
the UPS.
5. On/Off
To turn the UPS unit on, lightly press the power switch. To turn it off, press the power switch
again. Make sure that the power switch is kept in the "ON" position, otherwise the UPS will
be disabled and your equipment unprotected in the event of power failure.
Note: For maintenance purposes, please turn the UPS on before the PC and other loads,
and turn it off after the connected loads are turned off.
6. DC Start
X4 RT units are equipped with an integrated DC start function. To start the UPS in the
absence of a power supply and with a full battery, simply press the button.
7. Connect Modem/Phone/Network for surge protection
Connect a single modem/phone line to a surge protected "IN" outlet on the back panel of the
UPS unit. Connect the "OUT" outlet to the computer with another phone line cable.
Caution: The telephone line lightning arrester could be rendered inoperable if improperly
installed. This surge protection device is for indoor use only. Never install telephone wiring
during a lightning storm.
Note: This connection is optional.
6 . C O M P U T E R I N T E R F A C E
To prevent an abrupt computer system shutdown, connect a USB cable to your computer.
Then you can install and use the automatic shutdown software (free download from web
site).
The USB communication port at the back of the UPS enables the computer to directly
control UPS status.