wooden frame into the internal wall and make good the hole.
2.
Offer the fan box 6 up to the wall.
Screw the fan box 6 to the wooden frame using the slots in the flange
3.
(screws not supplied).
If mounting in a ceiling (flush mounting)
The surround 0 is not required.
1.
Insert the fan box 6 into the hole and mark four positions using the slots in
2.
the flange B.
Remove the fan box 6 from ceiling and fit the four ceiling clips (supplied)
3.
over the edge of the hole, so that the clips align with the marks on the ceiling B.
4.
Drill 4 pilot holes into the ceiling through the hole of each clip, ensuring not to
damage the clip.
Fit the ducting to the circular spigot 7.
5.
Offer the fan box 6 up to the ceiling.
6.
7.
Slit the cable grommet. Pass the electrical cable into the fan box 6 through
the front cable inlet hole.
Ensure cable grommet is in place and a tight fit.
Using the screws !¡ (Fig.B), fix the fan box flange to the ceiling clips.
8.
Terminating the ducting
Fit an outer grille (such as CFWG100, not supplied in the DX200/DX200T)
to the outer wall. For ceiling mounting, use appropriate ancillaries (not
supplied).
Wire the electrical connections
WARNING! THIS APPLIANCE MUST BE EARTHED
1.
Isolate the electricity supply and remove all fuses.
The terminal block will accept cable up to 1.5mm
2
2.
Use a double-pole isolating switch with a minimum contact gap of 3mm in
both poles.
3.
Use suitably rated 3-core or 4-core cable dependant on application.
4.
Remove the retaining screws of the terminal cover, if still in position.
Wire the fan as shown in F using the cable clamp provided. Check fan
5.
model to diagram.
DX200: "LH" =Live (High Speed)/ "LL" = Live(Low Speed)
6.
Replace the terminal cover 5 and fasten the retaining screws.
7.
See section on "User adjustments" if you wish to use settings other than
those that have been factory set.
8.
Refit the front cover(Fig.C).
Connect the cable from the isolating switch to electrical supply wiring, and
re-check installation.
10. Refit fuses before turning on electricity supply.
11. For fixed wiring circuits, the protective fuse for the appliance must not
exceed 5A.
For Australia Only
CF20 – Connection to the supply - flexible 3-core cable with 3 pin plug top for
insertion into an approved 10A wall mounted surface switch with at least 3mm
clearance between contacts.
ALL OTHERS – Permanently connected to the supply and a remote switch controls
operation. They should be directly wired to the supply through an approved 10A wall
mounted surface switch with at least 3mm clearance between contacts.
User adjustments
Before making any adjustments, isolate the fan completely from the mains
supply, check specification below to see which features apply to your fan.
Remove the front cover and replace after adjustment (Fig. C)
1.
DX200
There are no user adjustments for this fan.
DX200T
1.
The timer over-run period can be adjusted between approximately 30
seconds and 20 minutes. Use an electrician's screwdriver and turn screw "T"
(Fig.D), clockwise to increase time, anti-clockwise to decrease. (Factory
preset to approximately 10 minutes)
CF20
1.
The humidity setting is adjustable between approximately 50% and 90%
relative humidity. Use an electrician's screwdriver, and turn screw "RH"
(Fig.D), clockwise to increase the relative humidity setting and anti-clockwise
to decrease. (Note: the fan is more sensitive at 50% RH than at 90% and is
factory preset to approximately 70%).
CF20T
1.
The timer over-run period can be adjusted between approximately 30
seconds and 20 minutes. Use an electrician's screwdriver and turn screw "T"
(Fig.D), clockwise to increase time, anti-clockwise to decrease.
2.
The humidity setting is adjustable between approximately 50% and 90%
relative humidity. Use an electrician's screwdriver, and turn screw "RH"
(Fig.D), clockwise to increase the relative humidity setting and anti-clockwise
to decrease. (Note: the fan is more sensitive at 50% RH than at 90%).
Using the fan
DX200
Operate the fan using the external on/off switch. Repeat to switch off.
The fan speed is pre-set by the installer to either high or low speed. (If a change
over switch has been installed then the user can switch between high speed and
low speed.)
DX200T
Operate the fan using the external on/off switch. Repeat to switch off.
When the switch is turned off, the fan continues to operate for the selected over-
run timer period. Top Light "I" is lit when the external on/off switch is switched on.
The fan speed is pre-set by the installer to either high, medium or low speed.
Time delay start feature on or off
This is set by the installer to provide a 2-minute time delay start when the fan is
switched on using the external on/off switch.
CF20 / CF20T
Switched Operation
The fan can be wired with a separate on/off switch. Fan operates at condensation
speed when switched on. Top "Light I" is lit when the separate on/off switch is
switched on. When switched off, the fan will continue to operate if the humidity level
exceeds the set level. CF20T only: When switched off, the fan continues to operate
at condensation speed for the adjustable timer over-run period.
Condensation Operation
The fan operates at condensation control speed, when the relative humidity
exceeds the set level, and turns off when the humidity drops.
Boost Operation
The integral pull cord switch switches the fan to run at high speed. Bottom "Light
II" is lit when the fan is operating at high speed.
Note: If the separate on/off switch and integral pull cord are both on, then Lights "I"
and "II" will both be lit and the fan will run at high speed.
CF20T only
Time delay start feature on or off
This is set by the installer to provide a 2-minute time delay start when the fan is
switched on using a separate on/off switch.
Cleaning
Before cleaning, isolate the fan completely from the mains supply
Only clean the external surface of the fan, using a damp lint free cloth.
Do not use strong detergents, solvents or chemical cleaners
Allow fan to dry thoroughly before use.
Apart from cleaning, no other maintenance is required.
Key See Diagram E
7.
Circular Spigot
1.
Baffle Plate
8.
Clamp screws and wall plugs - 3 off
2.
Front Cover
9.
Fan Body Clamps – 3 off
3.
Impeller
10. Surround
11. Ceiling Screws 25mm long 4 off (Diagram B)
4.
Fixing Screws
5.
Terminal Cover
12. Foam Tape
6.
Fan Box
PLEASE LEAVE THIS LEAFLET WITH THE FAN FOR THE BENEFIT OF THE
USER
F
GB
Ancillary Options
Accessoires en option
Pour une installation rapide et
For speed and ease of
facile, il est préconisé de se munir
Installation, your installation may
des accessoires figurant sur la
require some of the Ancillaries
liste ci-dessous :
listed below:
WD100
Conduit mural
WD100
Wall Duct
CFWG100 Grille murale
CFWG100 Wall Grille
FDA
Kit d'adapteur de
FDA
Flat Duct Adaptor Kit
conduit plat
XCT100
Condensation Trap
XCT100
Trappe de
DGW/B
Air Replacement Door
condensation
Grille
DGW/B
Grille de porte de
SP100
Spigot Plate
remplacement d'air
XAA
Air Brick Adaptor
SP100
Plaquette pour ergot
XAA
Adaptateur de brique
VC10
Vent Cowl
perforée
WT10
Termination Ducting
VC10
Capuchon d'évent
Kit
WT10
Kit de terminaison de
XF/FM
Flat Ducting
conduit
(Plastic/Metal)
XF/FM
Conduit plat
(Plastic 234 x 29mm
(Plastique/Métallique)
Metal 230 x 25mm)
(Plastique 234 x 29 mm
VK10
Wall Vent Kit
Métallique 230 x 25 mm)
FD100
Flexible Ducting
VK10
Kit pour évent mural
WDC5
Worm Drive Clips
FD100
Conduit flexible
XCMK
Ceiling Mounting Kit
WDC5
Colliers à serrage par
XBP
In-Line Back Draught
vis sans fin
Shutter
XCMK
Kit pour montage au
EFT
Easy Fit Termination
plafond
XBP
Obturateur de
Kit
refoulement en
GMK
Glass Mounting Kit
ligne
PDXGF
Grease Filter
EFT
Kit de terminaisons à
Listed below are some of the
encliqueter
spares available. See back page
GMK
Kit de pose sur une
of this booklet for ordering details:
vitre
PDXGF
Filtre de graisse
41520SK Fixing kit (Entire kit)
41528SK Circular Spigot (Entire
Liste de quelques pièces de
Range)
rechange : Pour la commande,
41731SK Motor (DX200)
prière de se reporter à la dernière
41733SK Motor (CF20/CF20T/
page de cette notice :
DX200T)
41782SK PCB Assy (DX200T)
41520SK Kit de fixation (Kit
complet)
41735SK PCB Assy (CF20)
41528SK Ergot circulaire
41736SK PCB Assy (CF20T)
(gamme complète)
41737SK Front Cover c/w Baffle
41731SK Moteur (DX200)
(DX200)
41733SK Moteur (CF20/CF20T/
41738SK Front Cover c/w Baffle
DX200T)
(DX200T)
41782SK Carte imprimée
41739SK Front Cover c/w Baffle
(DX200T)
(CF20/CF20T)
41735SK Carte imprimée
41740SK Surround Moulding
(CF20)
(Entire Range)
41736SK Carte imprimée
41741SK Pull cord assembly
(CF20T)
(CF20/CF20T)
41737SK Couvercle avant avec
41742SK Impeller (Entire
chicane (DX200)
Range)
41738SK Couvercle avant avec
chicane (DX200T)
41739SK Couvercle avant avec
chicane (CF20/CF20T)
41740SK Moulure de cadre
(gamme complète)
41741SK Ens. interrupteur à
cordon (CF20/CF20T)
41742SK Hélice (gamme
complète)
D
NL
Zubehör
Accessoireopties
Die unten aufgeführten Produkte
Voor snelheid en gemak van
unterstützen eine schnelle und
installatie is het mogelijk dat u
problemlose Installation:
sommige van de onderstaande
accessoires nodig heeft.
WD100
Wandrohr
CFWG100 Wandgitter
WD100
Muurdoorvoer
FDA
Flachrohr-Adapter
CFWG100 Muurrooster
XCT100
Kondensationsfalle
FDA
Adapterkit voor plat
DGW/B
Luftaustauschtürgitter
kanaal
SP100
Zapfenplatte
XCT100
Condensaatvanger
XAA
Luftziegel-Adapter
DGW/B
Deurrooster voor
VC10
Lüftungskappe
luchtverversing
WT10
Bausatz für
SP100
Luchtinlaatplaat
Rohrabbruch/
XAA
Adapter voor
Rohrabschluss
gaatsteen
XF/FM
Flachrohr
VC10
Uitlaatkap
(Kunststoff/Metall)
WT10
Muurdoorvoerset
Kunststoff 234 x 29 mm,
XF/FM
Plat kanaal
Metall 230 x 25 mm
(plastic/metaal)
VK10
Bausatz für
(Plastic 234 x 29mm
Wandlüftungs
Metaal 230 x 25mm)
FD100
Flexibles Rohr
VK10
Muuruitlaatset
WDC5
Schneckenantriebs-
FD100
Flexibele slang
klemmen
WDC5
Schroefdraadklemmen
XCMK
Bausatz für
XCMK
Plafondmontagekit
Deckenmontage
XBP
Gealigneerde
XBP
In-Line-
achterste tochtklep
Durchzugsklappe für
EFT
Gemakkelijk te
die Rückseite
monteren aansluitingset
EFT
„Easy Fit" Bausatz für
GMK
Glasmontagekit
Rohrabbruch/
PDXGF
Oliefilter
Rohrabschluss
Hieronder vindt u een lijst van
GMK
Bausatz für
verkrijgbare reserveonderdelen.
Glasmontage
Verwijs naar de achterste pagina
PDXGF
Fettfilter
voor het bestellen ervan.
Unten aufgeführt sind einige
Ersatzteile. Auf der Rückseite
41520SK Montageset (volledig
dieses Hefts finden Sie
set)
Einzelheiten über die Bestellung:
41528SK Ronde luchtinlaat
(volledige reeks)
41520SK Befestigungsbausatz
41731SK Motor (DX200) **
(gesamter Bausatz)
41732SK Motor (DX200T) **
41528SK Rundzapfen
41733SK Motor (CF20/CF20T/
(gesamtes Sortiment)
DX200T)
41731SK Motor (DX200)
41734SK PCB montage
41733SK Motor (CF20/CF20T/
(DX200T)
DX200T)
41735SK PCB montage (CF20)
41782SK Flachbaugruppe
41736SK PCB montage
(DX200T)
(CF20T)
41735SK Flachbaugruppe
41737SK Bovendeel
(CF20)
ventilatorhuis met
41736SK Flachbaugruppe
schermplaat (DX200)
(CF20T)
41738SK Bovendeel
41737SK
Frontabdeckung C/W
ventilatorhuis met
Ablenkung (DX200)
schermplaat (DX200T)
41738SK
Frontabdeckung C/W
41739SK Bovendeel
Ablenkung (DX200T)
ventilatorhuis met
41739SK Frontabdeckung C/W
schermplaat
Ablenkung (CF20/CF20T)
(CF20/CF20T)
41740SK Einfassungsform
41740SK Lijstwerk voor
(gesamtes Sortiment)
montageplaat
41741SK Zugschnur
(volledige reeks)
(CF20/CF20T)
41741SK Trekkoordmontage
41742SK Gebläserad
(CF20/CF20T)
(gesamtes Sortiment)
41742SK Rotor (volledige
reeks)