Descargar Imprimir esta página

Publicidad

Enlaces rápidos

BATH MIXING PROGRAM
PROGRAMME DU MITIGEUR POUR LA SALLE DE BAIN
PROGRAMA MEZCLADORES BAÑO
Art. 39906
Installation of built-in parts
Installation des parties de l'encaissement
Instalación partes por empotrar
Gessi SpA - Parco Gessi
13037 Serravalle Sesia (Vercelli) - Italy
Phone +39 0163 454111 - Facsimile +39 0163 459273
www.gessi.com - gessi@gessi.it

Publicidad

loading

Resumen de contenidos para Gessi 39906

  • Página 1 PROGRAMA MEZCLADORES BAÑO Art. 39906 Installation of built-in parts Installation des parties de l’encaissement Instalación partes por empotrar Gessi SpA - Parco Gessi 13037 Serravalle Sesia (Vercelli) - Italy Phone +39 0163 454111 - Facsimile +39 0163 459273 www.gessi.com - gessi@gessi.it...
  • Página 2 MUST NEVER BE EXCEEDED, as it may damage and/or cause ruptures and/or leakages and/or even break the product, and present a potential hazard and danger to safety, health and/or property. Following are the technical data with respect to the installation of Gessi plumbing products. ► W orkingpressureshouldnotbelowerthan0,5bar(7,25psi)andnotbehigherthan5bar(72Psi).In case of higher working pressure use a pressure reducer valve.
  • Página 3: Attention - Avertissement

    Ci-dessous nous indiquons les données techniques concernant l’installation des produits sanitaires Gessi. ► L apressiondeservicenedoitpasêtreinférieureà0,5bar(7,25psi)etsupérieureà5bar(72Psi).En cas de pressions de service plus hautes utiliser une soupape de réduction de la pression.
  • Página 4: Cuidado - Advertencia

    1 - ¡CUIDADO!! LES ROGAMOS QUE TENGAN EN CUENTA QUE NUNCA la presión y/o la temperatura máximaaconsejadaNOTIENEQUESERSUPERADA,yaquepodríadañary/ocausarrupturasy/o pérdidasy/oaveríasdelproductoy,porlotanto,representarunriesgoyunpeligropotencialpara la seguridad, la saludad y/o la propiedad. A continuación Les proporcionamos los datos técnicos relativosalainstalacióndelosproductosdegriferíaGessi. ► L apresióndeejercicionotienequeserinferiora0,5bar(7,25psi)ysuperiora5bar(72Psi).Encaso depresionesdeejerciciomayores,utilicenunaválvuladereduccióndelapresión. ►Presiónmáximadeensayodurantelainstalación:8bar(116psi). ► E vitengrandesdiferenciasdepresiónentrelaalimentacióndelaguafríayaquelladelaguacaliente. Lasdiferenciasdepresión,elaguaconunalatocontenidomineralylassustanciasjabonosaspueden...
  • Página 5 PRE-INSTALLATION INFORMATION - PRÉALABLES - PRELIMINARES...
  • Página 6 PRE-INSTALLATION INFORMATION - PRÉALABLES - PRELIMINARES FROM THE CONTROL DE LA COMMANDE DEL CONTROL DN12 INmin.(l/min) IN max. (l/min) Pression(bar) OUT = 10 l/min OUT = 19 l/min 10,7 10,5 *Abovethesevaluesusetheflowratereducerincluded(19l/min)! *Audessusdecesvaleursutiliserleréducteurdedébitfourni(19l/min)! *Másalládeestosvalores¡utilicenelreductordecaudalincluidoenelsuministro(19l/min)!
  • Página 7 PRE-INSTALLATION INFORMATION - PRÉALABLES - PRELIMINARES - Installation tools - Outils nécessaires pour l’installation - Herramienta necesaria para la instalación...
  • Página 8 INSTALLATION - INSTALLATION - INSTALACIÓN Fig. 1 Fig. 2 Fig. 3 Plasterboard wall Tiled surface Mur en placoplâtre Surface carrelée Pared de cartón-yeso Superficie con baldosas...
  • Página 9: Instalación

    INSTALLATION - INSTALLATION - INSTALACIÓN INSTALLATION Before starting make sure the water network is off. Remove the protection plug of the thread to allow connection to the supply pipe. To create the proper seat for the built-in body check the actual overall sizes and consider the minimum and maximum built-in depths shown on the plastic protection pre-installed on the body.
  • Página 10 INSTALLATION - INSTALLATION - INSTALACIÓN Fig. 4 1/2”NPT - f Fig. 5 Fig. 6 use hemp or teflon employer chanvre ou teflon usarcáñamooteflon Fig. 7...
  • Página 11 INSTALLATION - INSTALLATION - INSTALACIÓN INSTALLATION (continues...) Position the supply pipe with proper connection for built-in body. Insert the body in the slot previously obtained in the wall. Connectthesupplypipestothebodyfollowingtheindicationsinthefigure.Werecommendusinghemp to guarantee tightness on the threads (WARNING: all connections on the built-in body have female 1/2”NPTthreads).
  • Página 12 INSTALLATION - INSTALLATION - INSTALACIÓN Fig. 8 OPEN Fig. 9 Fig. 10 Tiled surface Surface carrelée Superficie con baldosas...
  • Página 13 INSTALLATION - INSTALLATION - INSTALACIÓN INSTALLATION (continues...) Before next step carry out a test to check there are no leakages in the system. Fully embed the built-in body in the wall as much as possible adhering to its plastic protection. WARNING: check, with wall finished, that minimum and maximum built-in sizes shown on the plastic protection are complied with.
  • Página 14 NOTES - NOTES - NOTAS ..................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................
  • Página 16 ET42917-R0...