Osram LS/PD LT2 LI UF Manual De Instrucciones página 2

Ocultar thumbs Ver también para LS/PD LT2 LI UF:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6
GB LS/PD LT2 LI UF
Sensor for OTi DALI
Ultrafl at LED drivers
1)
Connection (Master/Slave) 2)
Operating voltage 3)
Power consumption 4)
Sensor connection 5)
External Push button connection total wire length 6)
External push button 7)
Light sensing range 8)
t a
t c 9)
Type of protection 10)
Wire preparation /
Anschluss Vorbereitung
Wiring scheme
with two LED drivers /
Anschluss-Schema
16)
mit zwei LED Treibern
Presence detection range (= usage at workplaces) /
Präsenzerfassungsbereich (= Einsatz an Arbeitsplätzen)
SAFETY AND MOUNTING INFORMATION:
The LS/PD LT2 LI UF sensor is exclusively designed for luminaire integration. If the sensor interface is connected to an external voltage, particular to
mains voltage, the unit will be destroyed! As the LEDset interface of the LED driver is not galvanically separated from the mains connection of the driver,
the sensor interface must not be touchable and the unit has to be put out of operation when the housing or the PIR lens is damaged. 1) Light and pres-
ence sensor exclusively designed for OTi DALI Ultraflat LED drivers; 2) Connection interface; 3) Operating voltage; 4) Power consumption; 5) Allowed wire
connection length to the LED drivers per output; 6) Allowed total wire length to all external push buttons; 7) Suitable push button: 230VAC type with push
to make contact; 8) Light sensor range of operation (measured at the sensor); 9) Max. allowed casing temperature at the test point; 10) Type of protection;
11) Dimension drawing; 12) Optional restriction of detection range to ~50% by click-on shutters; 13) Recommended wire preparation, wire with basic
insulation required; 14) Wiring scheme with one LED driver; 15) External push button; 16) Wiring scheme with two LED drivers; 17) Presence detection
range at working place applications; 18) Presence detection range at 2m mounting height; 19) Presence detection range at 3m mounting height; 20) Mo-
tion detection range at corridor use case applications; 21) Motion detection range at 2m mounting height; 22) Motion detection range at 3m mounting
height; 23) Motion detection range at 4m mounting height
OSRAM GmbH
Steinerne Furt 62
86167 Augsburg
Germany
www.osram.com
LEDset / LED-aux
5V DC
30mW
≤ 1m
≤ 25m
230 V AC
10...1000 lx
0...+50 °C
55 °C
IP20
Wiring scheme with one LED driver /
13)
Anschluss-Schema mit einem LED Treiber
15)
15)
2 m mounting height
3 m (=max) mounting height
Dimensions /
11)
Abmessungen
9)
Motion detection range (= usage in corridors) /
17)
Bewegungserfassungsbereich (= Einsatz in Korridoren)
18)
19)
2
Restrict detection range /
Erfassungsbereich einschränken
14)
2 m mounting height
3 m mounting height
4 m (=max) mounting height
12)
20)
21)
22)
23)

Publicidad

Tabla de contenido
loading

Tabla de contenido