charcoal filter can then be removed. The new filters must be inserted in the correct order, i.e.,
activated charcoal filter at the bottom/particle filter at the top. This ensures that the particle filter lies
upstream of the activated charcoal filter in the airflow and keeps dust from covering the activated
charcoal filter. The cover can then be replaced onto the housing and the toggle-type fasteners can be
closed again. Finally, the power supply can be reconnected.
3 Errors
Error
Device not working
Red volume flow light
The device shows a saturation
error immediately after the
heating phase
The red warning light for filter
saturation is on and the airflow
has been interrupted
4 Technical Specifications
Volume flow
Monitoring
LED display
Signal output
Voltage
Current consumption
Motor protection
Switching capacity – floating
outputs
Weight
Allowable storage temperature
Allowable operating temperature
21
Errors
Cause
No voltage
Defective device
Defective blower
Outgassing of materials from
the interior
Activated charcoal filter is
saturated
approx. 30 m³/h
- blower function
- saturation of activated charcoal filter
RED / error – GREEN / RUNNING
floating output for blower function and saturation
230 V / 50 Hz
As 0,15 A
against voltage reversal; electrical blocking and overload
protection
max. 230V / max. 5A
15 kg
-20 °C to +60 °C
0 °C to +40 °C
Troubleshooting
Check mains voltage
Send in device
Send in device
Disconnect the mains plug,
open the cover, remove the
filters and ventilate for several
minutes. Re-insert the filters in
the correct order, close the
cover and restart the device
Replace filter