12. QUICK VIEW OF BASIC SETTINGS

From the main screen, where the current time and date are indicated, with a press on the +
button we can quickly view some basic settings of the device configuration, such as the software
version, the operating hours of the pumps, if a pump is running, etc...
13. WARNINGS MANAGEMENT
One of the main premises of the device is to try to minimize the interruption of the hydraulic
supply as far as possible. For this, there is an auto reset system that, in case of reading the motor
consumption outside the established values, both due to excess consumption (over consumption)
and by default (dry running) allows the reactivation of the system after a few minutes, without
requiring the intervention of the installer.
the installer in order to avoid a future problem on the pump motor.
In turn, we have control over the frequency of system starts, which, if
very frequent, can indicate an anomaly in the hydraulic installation that,
if corrected quickly, can extend the useful life of the motors.
We also have a setting that prevents the system pump(s) from remaining
for many days without starting. To do this, if we enable this function,
we can configure every few days of inactivity we force a start of a few
seconds, preventing the motor from locking.
We can program the activation of relays 1 or 2, individually, to activate
the case of starting pump 1, starting pump 2, starting any of the pumps
(only in the device for 2 pumps), of pump 1 failure, of pump 2 failure
(only in the device for 2 pumps), of the input of over level of the
tank, of the push of the manual stop button, of the activation of the
stop of the automatic system or finally we can add a time schedule
independent of the state of the pumps to activate/deactivate the relay
that we are configuring.
We can view the operating hours of pump 1 and pump 2 individually.
We have an independent register for pump 1 and pump 2 where we
can check over time the failures due to over consumption or due to dry
work that they have had. We have multiple records per pump where
we can see the time and date when the failure occurred.
The device software version is displayed.
The factory reset will erase all existing device settings except the
working hours of the pumps and their fault history.