L40 Blue Wire Service Kit
A. Removal of the original wires.
1. Remove the two screws securing the cover to the
control box. See Fig.1.
FIG. 1
2. Locate the two blue wires from the harness and cut
them to 4 inches. See Fig. 2.
FIG. 2
Cut blue wires to
4 in.
Blue wires
Disconnect the blue wire terminals from
the gas control valve
3. Loosen the liquid tight nut and pull the blue wires
through the connector. Disconnect and discard the blue
wires from the gas control valve. See Fig. 2.
Installation Instructions •
B. Installation of new wires
1. Strip the end of the blue harness wires in the control
FIG. 3
2. Connect the terminals of the new blue wires to the gas
FIG. 4
3. Insert the stripped ends of the new blue wires through
FIG. 5
L40 Blue Wire Service Kit
box. See Fig. 3.
valve as shown in Fig. 4.
the black tube. Insert the black tube and the stripped
blue wires through the liquid tight connector, as shown
in Fig. 5.
Strip the blue
wires back ¼"