FINAL CHECK
The most important test phases are described below and must be carried out by qualified personnel in full
compliance with the current laws and regulations:
• Read the instructions given under installation warnings
• Check the resistance value of the sensing device (8K2± 10%)
• Connect the sensing device and check that the yellow LED and the red LED come on.
• Activate the sensing device and check that the red LED immediately goes off and the yellow LED after 2
seconds.
• Deactivate the sensing device and check that the two LEDs immediately come on.
• If the TEST input is used, check that the control unit to which it is connected properly runs the procedure.
MAINTENANCE
Gi.Bi.Di. recommends regular maintenance every 12 months by qualified personnel in order to assure
safety according to current regulations.
DSC90 DISPOSAL
Gi.Bi.Di advises recycling the plastic components and to dispose of them at special
authorised centres for electronic components thus protecting the environment from
polluting substances.
CE DECLARATION OF CONFORMITY
The manufacturer:
Declares that the products:
Are in conformity with the following CEE Directives:
• EMC Directive 2004/108/CE and subsequent amendments
and that the following standards have been applied:
• EN61000-6-2, EN61000-6-3
Date 14/12/09
GI.BI.DI. S.r.l.
Via Abetone Brennero, 177/B,
46025 Poggio Rusco (MN) ITALY