How The System Works; Setting Up The System - infaco DSES F3015 Manual De Instrucciones

Ocultar thumbs Ver también para DSES F3015:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26

How the system works

The user should always wear the knitted conductive glove on the hand which is NOT
holding the appliance :
- The conductive glove no. 8 gives information to the electronics to re-open the appliance in
the event of contact with the cutting head.
Note : an inner glove (ref.356S) can be used for comfort but is not necessary.
Make sure you do not use inner glove for comfort and the conductive glove the wrong way round.
To differentiate between them: only the conductive glove no. 2 has a Velcro patch.
You must use only INFACO conductive gloves.
DSES & DSES WIRELESS glove
On the side of the hand opposite the shear Ref. Right & Left 355G29 - 355G29G
You must disconnect the secateurs for all these operations.
Do not use any outer glove over the INFACO conductive glove.

Setting up the system

1
2
n°1
n°3
n°2
n°3
Slip the plug no. 1 through the eye hole no. 3
Put the fix tongue no. 2 through the eye hole no. 3
14

Publicidad

Tabla de contenido
loading

Tabla de contenido