1
Operating Instruction for Swimming Pool Heat Pumps Heatermax 15 / 20 / 30 / 50
Swimming Pool Heat Pumps
Swimming Pool Heat Pumps
Dear Customer,
Dear Customer,
We congratulate you on the purchase of a swimming pool heat pump of the series HEATERMAX.
We congratulate you on the purchase of a swimming pool heat pump of the series HEATERMAX.
This operating instruction contains important information helpful for correct installation, operation and maintenance of the swimming pool heat pump.
This operating instruction contains important information helpful for correct installation, operation and maintenance of the swimming pool heat pump.
Please read the operating instruction thoroughly and keep it well.
Please read the operating instruction thoroughly and keep it well.
The Heatermax pool heat pump will heat your pool water and keep it at a constant temperature level when the ambient air temperature is at 7 to 430C
Dimensions
Modell
Heatermax 15/20
A
B
C
D
E
F
G
H
Technical Data
Model
Article no.
Voltage / Phase / Frequency
Rated Current
Advised Fuse
Recommended Power Cable (not included)
Class of Protection
Type of Protection
Heating Capacity at condition 1: Air 27°C / Water 27°C / Humidity 80%
Heat Output
Power Consumption
Coefficient of Performance (COP)
Heating Capacity at condition 2: Air 15°C / Water 26°C / Humidity 70%
Heat Output
Power Consumption
Coefficient of Performance (COP)
Max. Pool-volume
Min. water flow rate
Max. water pressure
Water Temperature (operating range)
Air Temperatur (operating range)
Inlet / Outlet
Compressor (type/brand)
Fan Direction
Noise level at 1m
Noise level at 10m
Cabinet
Stabilizing studs (included)
Heating Exchanger (Condenser)
Refrigerant Gas R410A
Length
Width
Height
Net weight
Above data are subject to modification without notice.
Safety Instructions
Safety Instructions
WARNING!
WARNING!
According to the harmonized European Directives and Safety Standards, the installation, service and repair of the appliance as well as the installation and/or maintenance of the mains voltage cable must be carried
According to the harmonized European Directives and Safety Standards, the installation, service and repair of the appliance as well as the installation and/or maintenance of the mains voltage cable must be carried
out by an approved and qualified electrician. Before beginning any installation, operation, service or maintenance work, the qualified electrician responsible for these tasks must have read and understood the
out by an approved and qualified electrician. Before beginning any installation, operation, service or maintenance work, the qualified electrician responsible for these tasks must have read and understood the
operating instructions.
operating instructions.
Manual Heatermax Innenteil 2015.indd 10
Heatermax 30
273
330
420
680
260
280
293
360
747
930
210
230
83
83
520
565
Heatermax 15
7504629
3,40 A
10 A
I
IP X4
3,50 kW
0,78 kW
4,5
3,00 kW
0,77kW
3,9
15 m
3
3,5 m3/h
10 kPa
46 dB(A)
37 dB(A)
4 pcs.
600 g
747 mm
293 mm
520 mm
32 kg
Heatermax 50
330
655
300
360
1000
340
83
620
Heatermax 20
7504630
220-240 VAC / 1 PH / 50 Hz
4,90 A
10 A
H07RN-F 3 x 2,5 mm
I
IP X4
5,00 kW
1,14 kW
4,4
3,70 kW
0,97 kW
3,8
20 m
3
3,5 m3/h
11 kPa
15°C - 35°C
7°C - 43°C
50 mm
rotary / Hitachi
Horizontal
46 dB(A)
37 dB(A)
galvanized steel, anti-rust
4 pcs.
Titanium (in PVC reservoir)
650 g
747 mm
293 mm
520 mm
36 kg
13
Heatermax 30
Heatermax 50
7504631
7504631
7,90 A
10,60 A
10 A
15 A
2
I
I
IP X4
IP X4
8,50 kW
11,50 kW
1,81 kW
2,45 kW
4,7
4,7
5,60 kW
8,20 kW
1,44 kW
2,10 kW
3,9
3,9
30 m
3
50 m
3
5,7 m3/h
5,7 m3/h
12 kPa
14 kPa
48 dB(A)
52 dB(A)
39 dB(A)
43 dB(A)
4 pcs.
4 pcs.
950 g
1200 g
930 mm
1000 mm
360 mm
360 mm
565 mm
620 mm
47 kg
61 kg
12.11.15 16:13