Composition Of The Product - Palazzetti FC 810 Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

GB
User's Manual Thermoregolator
L2
L3
L4
L1
L5
DP1
MENU
P1
P2
P3
P4
Fig. 1
External aspect and electrical connections
1.0 OVERVIEW
The electronic regulator (fig.1) has been designed for managing air fireplaces. Being versatile it is usable in a
wide range of applications. Display and leds allow the visualisation of temperatures and outputs states and
mark eventual breakdowns.

2.0 COMPOSITION OF THE PRODUCT

Boxed temperature controller 3 module can fit plates AVE and VIMAR. It is provided with codified
internal connection for electrical connection to:
Supply
Fan
IN 'Spark'
Temperature Probe
Cover plate
Inbox box
Temperature Probe in Teflon cable length 2,00 Mt, bulb 100 mm diameter 3 mm
Ogive to fix the Probe + nut + washer
Connecting cable for the grounding
Screwed terminal with nipple for the general grounding connection
Instructions
3.0 MANUAL FOR THE USE AND THE MANTEINANCE
3.1 MENU
Selection functioning modality
Not available for model with input for thermostat [Cod. 2]
Pressing the P4 key enters the current modality signalled by the display and by the led
Pressing again the P4 key select cyclically one of the three functioning typologies signalled by
the display and by the led
After about 3 seconds the setting is automatically memorised and the current speed is visualised
Selection functioning speed
Pressing P2 or P3 keys the setting of the current fan speed is visualised or modified
P0= off (only in MANUAL modality); P1 = minimum speed; P10= maximum speed
The function to modify the speed is not available in the modality PROPORTIONAL
In modality AUTOMATIC the speeds that can be set are P1 ÷ P10
Function SPARK
Actionable only in determined fireplaces.
Pressing the P1 key activates the relative kit spark exit: the device shows the blinking advice
'Sci' for 2 sec. The signal is on until the ignition of the fireplace.
3.2 FUNCTIONING
On/Off:
The on/off of the controller is pushing the button P4
The state OFF is signalled through the led DP1
3.2.1 MODELS WITH THERMOSTAT
Functioning Modality
Function AUTOMATIC: indicator signal AUT
If the controller is on, the fan starts functioning when the air temperature is hot, on the display is
shown the value of the setting power. If the temperature is low appears the advice Aut
FC 810
PROBE
FUSE
10
1 2 3 4 5 6 7 8
OUT 'Spark'
[Cod. 2]
9

Publicidad

Tabla de contenido
loading