3.2.2 MODELS WITH AERAULIC PROBE IN
Function STANDBY:
If the device is OFF, and the fireplace is OFF
The device starts automatically the state ON
Modality FUNCTIONING
Function MANUAL: advice signal MAN
The fan is at the maximum speed independently by the fireplace's temperature
Function AUTOMATIC: advice signal AUT
The fan starts functioning when the air temperature is hot
Function PROPORTIONAL: advice signal PROP
The fan increases automatically its speed according to the temperature read by the probe.
The led L5 indicates the fan activation state
Function SECURITY:
If the probe's temperature is high, the fan is off and the modality is MANUAL
The device starts the PROPORTIONAL modality initially waiting 10 seconds.
After security, if the functioning conditions are the same, the device goes back to the previous
modality
Function ALARM:
If the temperature read by the probe is higher than in the fireplace
The acoustic signal is activated;
the fan works at the maximum speed to diminish the over–heating ;
the signal could be deactivated for 5 minutes pushing a button;
After 5 minutes if there's is again conditions of alarm, it is activated again.
3.3 FAILURE OR ALARM SIGNALS
The controller has the signal failure of the probe [Cod=1]
Blinking message for the failure signal:
Lo : indicates a low temperature
Hi: indicates a high temperature
4.0 MANUAL FOR THE INSTALLER
All the following procedures have to be made by experienced and qualified personal because wrong
parameters' changing could make the product not adequate for a good functioning
4.1 SECONDARY Menu
It allows to modify the functioning parameters of the controller.
To enter the MENU push together buttons P2 and P3 for about 5 seconds
To visualise the parameters use button P2 or P3
To show the parameter's value push the button P4
To modify the parameter's value push buttons P2 or P3
To visualise again the parameters' list and memorise push button P4
To exit and memorise wait for about 5 seconds
Parameters are described in the following table
4.1.1 Calibrations/Setting out
Table 1
Parameters SECONDARY Menu
Temperature activation Fan
[°C]
Temperature activation Alarm
[°C]
Temperature activation security
[°C]
Activation function SECURITY
Activation function STANDBY
Fan speed [for P01]
Fan speed [for P09]
Regulation interval for proportional modality [°C]
Setting out code IN Probe
1= Probe
2= Thermostat
[Cod. 1]
(temperature under 0°C): Probe open/disconnected
(temperature over 180°C) :Probe in short circuit
Product
Product
Symbol
00252001
002520016
4
SEt
45
45
tAL
130
130
tSi
100
100
SiC
1 [on]
1 [on]
Stb
1 [on]
1 [on]
UUE
30
35
UEn
70
70
DEL
45
45
Cod
1
2
GB
Range
40 ... 99
100 ... 180
80 ... 140
0 ... 1
0 ... 1
00 ... 99
00 ... 99
20 ... 50
1 ... 2