GB
Function
The
'insert') is a component of the blind/shutter control system and is used in combination
with
the
the
The insert is installed in a flush-mounting box as per DIN 49073 (deep box recommended).
Motor
The insert can only be used in combination with the above-mentioned shutter control
N
L
timers.
12
shutter control insert without extension input
(in the following text referred to as
shutter control timer
or
shutter control timer ' comfort'
GB
The insert is equipped with 2 heavy-duty relay contacts interlocked with each other to
prevent simultaneous activation of the shutter motor in both directions of movement
and thus damage to the motor (see fig.).
Each insert can be used to control one motor with limit switch of up to 1000 W
max. Observe the instructions of the motor manufacturer.
The insert is equipped with 4 connecting terminals ( N,
to establish the electrical contact with the adapter.
Aditionally, a 3-pole terminal (supplied with the sun sensor) can be placed inside the
insert. This terminal ensures the connection of the sun sensor in the event of embedded
laying of the sensor cable when the insert is used in combination with the
timer 'comfort'
.
, L) and a connector
,
shutter control
13