RS-485/422 Connector
Two 2-pin terminal blocks for RS485/RS422 serial
interface. The serial port can be configured to support:
• Two-wire RS485 half duplex
• Four-wire RS485 full duplex
• Two-wire RS422 simplex
• Four-wire RS422 full duplex point to point
communication
Function
RS485/RS422 RX/TX
A
RS485/RS422 RX/TX
B
RS485/RS422 TX A
RS485/RS422 TX B
SD Card Slot
Supports microSD cards with up to 64 GB of storage. For best recording performance, use a
microSDHC or microSDXC card with speed class 10.

Install the Hardware

Mount the video encoder

The AXIS M7016 is supplied with a mounting kit containing brackets. The unit can be mounted in
a rack or on a wall.
After removing the existing 4 screws, attach the mounting brackets to the video encoder at an
angle suitable for installation in a standard 1U 19" rack, or on the wall.
Mounting on a wall
1. Position the video encoder against the wall with the brackets attached, and mark the
four mounting holes, two for each bracket.
2. Drill the four mounting holes.
3. Attach the video encoder to the wall using appropriate screws.