confi guring the settings
Open the door, turn the control and select:
the "EXPERT" ed il livello "HOT - - WATER" level, then:
• press the programming button
• turn the control and select the "PARALLEL DHW" parameter;
• press the programming button
iset the "CODE- -NO" at "0000" by pressing the button four times
• press the programming button
PARAMETER
PARALLEL DHW
PARALLEL DHW
Ruotare LA MANOPOLA SELEZIONARE IL PARAMETRO "T - - HS DHW"
(red LED on);
DISPLAY SCREEN
0 0
PRESS THE PROGRAMMING BUTTON "
PRESS THE PROGRAMMING BUTTON "
FIGURE
DESCRIPTION
Turn the control and set:
=> 00 : to disable the priority of the boiler, hea-
ting, pumps and mixers (recommended);
=> 01 : to disable partial priority of the boiler,
heating, pumps and mixers. When the
collector reaches its temperature setting,
the mixers are enabled (and not the pum-
ps), but if the temperature of the collector
decreases again (greater demand for the
boiler), the mixing valves are disabled im-
mediately;
00
=> 02 : PARTIAL parallel operation, the pumps
of the direct circuits (without mixers) are
stopped while the mixers work to main-
tain the operating temperature;
=> 03 : TOTAL parallel operation, all the hea-
ting circuits are activated, including the
pumps of the direct circuits. CAUTION
Using the "02 or 03" parameters greatly increa-
ses the time required for the boiler to get up
to temperature, aff ecting the Total yield as a
result.
"
" (